vane anemometer BA16

Table of contents

Notes regarding the operating manual................................. 2

Safety ..................................................................................... 2

Information about the device................................................ 3

Transport and storage........................................................... 5

Operation ............................................................................... 5

Maintenance and repair ........................................................ 6

Errors and faults.................................................................... 6

Disposal ................................................................................. 7

Notes regarding the operating manual

Symbols

Warning of electrical voltage

This symbol indicates dangers to the life and health of
persons due to electrical voltage.

Warning

This signal word indicates a hazard with an average
risk level which, if not avoided, can result in serious
injury or death.

Caution

This signal word indicates a hazard with a low risk
level which, if not avoided, can result in minor or
moderate injury.

Note

This signal word indicates important information (e.g.
material damage), but does not indicate hazards.

Info

Information marked with this symbol helps you to carry
out your tasks quickly and safely.

Follow the manual

Information marked with this symbol indicates that the
operating manual must be observed.

You can download the current version of the operating manual
and the EU declaration of conformity via the following link:

BA16

https://hub.trotec.com/?id=40844

Safety

Read this manual carefully before starting or using the
device. Always store the manual in the immediate vicinity
of the device or its site of use!

Warning
Read all safety warnings and all instructions.

Failure to follow the warnings and instructions may
result in electric shock, fire and / or serious injury.

Save all warnings and instructions for future
reference.

This appliance can be used by children aged from
8 years and above and persons with reduced physical,
sensory or mental capabilities or lack of experience
and knowledge if they have been given supervision or
instruction concerning use of the appliance in a safe
way and understand the hazards involved.
Children shall not play with the appliance. Cleaning and
user maintenance shall not be made by children
without supervision.

Do not use the device in potentially explosive rooms.

Do not use the device in aggressive atmosphere.

Do not immerse the device in water. Do not allow liquids to
penetrate into the device.

The device may only be used in dry surroundings and must
not be used in the rain or at a relative humidity exceeding
the operating conditions.

Protect the device from permanent direct sunlight.

Do not expose the device to strong vibrations.

Do not remove any safety signs, stickers or labels from the
device. Keep all safety signs, stickers and labels in legible
condition.

Do not open the device.

Observe the storage and operating conditions as given in
the Technical data chapter.

Summary of Contents for BA16

Page 1: ...TRT BA BA16 TC2019 39 002 EN BA16 EN OPERATING MANUAL VANE ANEMOMETER ...

Page 2: ...s store the manual in the immediate vicinity of the device or its site of use Warning Read all safety warnings and all instructions Failure to follow the warnings and instructions may result in electric shock fire and or serious injury Save all warnings and instructions for future reference This appliance can be used by children aged from 8 years and above and persons with reduced physical sensory...

Page 3: ...ckaging lying around Children may use it as a dangerous toy Warning The device is not a toy and does not belong in the hands of children Warning Dangers can occur at the device when it is used by untrained people in an unprofessional or improper way Observe the personnel qualifications Caution Keep a sufficient distance from heat sources Note To prevent damages to the device do not expose it to ex...

Page 4: ... Value Model BA16 Temperature Measuring range 10 C to 60 C 14 F to 140 F Accuracy 1 5 C 3 0 F Measuring range resolution 0 1 C 0 1 F Air velocity Measuring range 1 00 m s to 30 00 m s 196 ft min to 5900 ft min 3 6 km h to 108 0 km h 2 2 mph to 67 0 mph 1 9 kn to 58 0 kn Accuracy 3 0 20 m s 3 40 ft min 3 0 8 km h 3 0 4 mph 3 0 4 kn Measuring range resolution 0 01 m s 1 ft min 0 1 km h 0 1 mph 0 1 k...

Page 5: ...d to condensation forming on the device s circuit board This physical and unavoidable effect can falsify the measurement In this case the display shows either no measured values or they are incorrect Wait a few minutes until the device has become adjusted to the changed conditions before carrying out a measurement Switching the display illumination on and off 1 Press the HOLD lamp button 5 for app...

Page 6: ... minutes of non use Please proceed as follows to deactivate the automatic switch off function ü The device is switched off 1 Additionally press the UNITS button 6 when switching the device on ð The indication disAPO appears on the display ð Automatic switch off is deactivated Info Note that the automatic switch off function is activated upon the next switch on If you do not like to use the functio...

Page 7: ...ww trotec24 com The separate collection of waste electrical and electronic equipment aims to enable the re use recycling and other forms of recovery of waste equipment as well as to prevent negative effects for the environment and human health caused by the disposal of hazardous substances potentially contained in the equipment In the European Union batteries and accumulators must not be treated a...

Page 8: ...Trotec GmbH Grebbener Str 7 D 52525 Heinsberg 49 2452 962 400 49 2452 962 200 info trotec com www trotec com ...

Reviews: