Trotec 3510205031 Original Instructions Manual Download Page 2

2

EN

moisture indicator BM31

Table of contents

Notes regarding the instructions  ......................................... 2

Safety ..................................................................................... 2

Information about the device................................................ 4

Transport and storage........................................................... 5

Operation ............................................................................... 5

Dielectric measurements ...................................................... 6

Maintenance and repair ........................................................ 8

Errors and faults.................................................................... 8

Disposal ................................................................................. 8

Notes regarding the instructions

Symbols

Warning of electrical voltage

This symbol indicates dangers to the life and health of
persons due to electrical voltage.

Warning

This signal word indicates a hazard with an average
risk level which, if not avoided, can result in serious
injury or death.

Caution

This signal word indicates a hazard with a low risk
level which, if not avoided, can result in minor or
moderate injury.

Note

This signal word indicates important information (e.g.
material damage), but does not indicate hazards.

Info

Information marked with this symbol helps you to carry
out your tasks quickly and safely.

Follow the manual

Information marked with this symbol indicates that the
instructions must be observed.

You can download the current version of the instructions and
the EU declaration of conformity via the following link:

BM31

https://hub.trotec.com/?id=43574

Safety

Read this manual carefully before starting or using the
device. Always store the manual in the immediate vicinity
of the device or its site of use.

Warning
Read all safety warnings and all instructions.

Failure to follow the warnings and instructions may
result in electric shock, fire and/or serious injury.

Save all warnings and instructions for future
reference.

The device is supplied with warning signs. Prior to initial
start-up, make sure to paste the corresponding warning
signs in your local language over the ones present at the
rear of the device as described in chapter Operation.

Do not use the device in potentially explosive rooms or
areas and do not install it there.

Do not use the device in aggressive atmosphere.

Do not immerse the device in water. Do not allow liquids to
penetrate into the device.

The device may only be used in dry surroundings and must
not be used in the rain or at a relative humidity exceeding
the operating conditions.

Protect the device from permanent direct sunlight.

Do not expose the device to strong vibrations.

Do not remove any safety signs, stickers or labels from the
device. Keep all safety signs, stickers and labels in legible
condition.

Do not operate the device near medical equipment (e.g.
pacemakers).

Do not open the device.

Do not operate the device near open electrical wiring.

Never charge batteries that cannot be recharged.

Different types of batteries and new and used batteries
must not be used together.

Insert the batteries into the battery compartment according
to the correct polarity.

Summary of Contents for 3510205031

Page 1: ...TRT BA BM31 TC220926TTRT02 002 EN BM31 EN ORIGINAL INSTRUCTIONS MOISTURE INDICATOR ...

Page 2: ...vicinity of the device or its site of use Warning Read all safety warnings and all instructions Failure to follow the warnings and instructions may result in electric shock fire and or serious injury Save all warnings and instructions for future reference The device is supplied with warning signs Prior to initial start up make sure to paste the corresponding warning signs in your local language ov...

Page 3: ...ot use the device in potentially explosive atmospheres for measurements in liquids or at live parts Any unauthorised changes modifications or alterations to the device are forbidden Personnel qualifications People who use this device must have read and understood the instructions especially the Safety chapter Residual risks Warning of electrical voltage There is a risk of a short circuit due to li...

Page 4: ...ant measuring spots to extract material for the CM measurement A max min function is available for the assessment of the measurements The measuring device comes equipped with a selectable display illumination When not in use an automatic switch off saves the battery Device depiction 1 2 3 4 No Designation 1 Sensor 2 Battery compartment with cover 3 Operating elements 4 Display Operating elements 5...

Page 5: ... direct sunlight the storage temperature complies with the values specified in the Technical data Remove the batteries from the device Operation Inserting the batteries Insert the supplied battery before first use Note Make sure that the surface of the device is dry and the device is switched off 1 Open the battery compartment at the rear of the device by sliding down the cover 14 2 Use the batter...

Page 6: ... 1 Press the Lamp button 5 ð The background illumination is activated 2 Press the Lamp button 5 again ð The background illumination is deactivated Switching the device off Info The device automatically switches off after approx 30 seconds of non use Please proceed as follows for manual switch off 1 Press the on off switch 8 ð The device is switched off Dielectric measurements The measuring device ...

Page 7: ...hich then simulates high moisture values Consequently a too high measured value will be displayed If the material to be measured contains metal e g nails screws lines pipes etc and is situated within the sensor s measuring field the measured value skyrockets due to intense reflections From visual inspection it is not always apparent whether there are any electrically conducting substances inside t...

Page 8: ...2 19 EU It states that this device must not be disposed of with the household waste at the end of its life You will find collection points for free return of waste electrical and electronic equipment in your vicinity The addresses can be obtained from your municipality or local administration You can also find out about other return options that apply for many EU countries on the website https hub...

Page 9: ...Trotec GmbH Grebbener Str 7 D 52525 Heinsberg 49 2452 962 400 49 2452 962 200 info trotec com www trotec com ...

Reviews: