moisture indicator BM31

Comparison chart material moisture

LCD display (digits)

0

10

20

30

40

50

60

70

80

90

100

dry

normal

damp

plaster and
anhydrite in M/
CM% (M% =
CM%)

0.3

0.5

1.4

2.0

2.5

2.7

%

cement-based
materials in
CM%

1.5

2.1

3.0

3.5

4.0

CM%

cement-based
materials in
mass %

2.7

3.6

4.5

5.5

6.0

M%

CM% = percentage due to calcium carbide method

M% = mass %

Maintenance and repair

Battery change

A battery change is required when the battery indication (9) is
displayed or the device can no longer be switched on (see
chapter Inserting the battery).

Cleaning

Clean the device with a soft, damp and lint-free cloth. Make
sure that no moisture enters the housing. Do not use any
sprays, solvents, alcohol-based cleaning agents or abrasive
cleaners, but only clean water to moisten the cloth.

Repair

Do not modify the device or install any spare parts. For repairs
or device testing, contact the manufacturer.

Errors and faults

The device has been checked for proper functioning several
times during production. If malfunctions occur nonetheless,
check the device according to the following list.

Disposal

Always dispose of packing materials in an environmentally
friendly manner and in accordance with the applicable local
disposal regulations.

The icon with the crossed-out waste bin on waste

electrical or electronic equipment is taken from Directive
2012/19/EU. It states that this device must not be disposed of
with the household waste at the end of its life. You will find
collection points for free return of waste electrical and electronic
equipment in your vicinity. The addresses can be obtained from
your municipality or local administration. You can also find out
about other return options that apply for many EU countries on
the website https://hub.trotec.com/?id=45090. Otherwise,
please contact an official recycling centre for electronic and
electrical equipment authorised for your country.
The separate collection of waste electrical and electronic
equipment aims to enable the re-use, recycling and other forms
of recovery of waste equipment as well as to prevent negative
effects for the environment and human health caused by the
disposal of hazardous substances potentially contained in the
equipment.

 In the European Union, batteries and accumulators must

not be treated as domestic waste, but must be disposed of
professionally in accordance with Directive 2006/66/EC of the
European Parliament and of the Council of 6 September 2006
on batteries and accumulators. Please dispose of batteries and
accumulators according to the relevant legal requirements.

Only for United Kingdom

According to Waste Electrical and Electronic Equipment
Regulations 2013 (SI 2013/3113) (as amended) and the Waste
Batteries and Accumulators Regulations 2009 (SI 2009/890) (as
amended), devices that are no longer usable must be collected
separately and disposed of in an environmentally friendly manner.

Summary of Contents for 3510205031

Page 1: ...TRT BA BM31 TC220926TTRT02 002 EN BM31 EN ORIGINAL INSTRUCTIONS MOISTURE INDICATOR ...

Page 2: ...vicinity of the device or its site of use Warning Read all safety warnings and all instructions Failure to follow the warnings and instructions may result in electric shock fire and or serious injury Save all warnings and instructions for future reference The device is supplied with warning signs Prior to initial start up make sure to paste the corresponding warning signs in your local language ov...

Page 3: ...ot use the device in potentially explosive atmospheres for measurements in liquids or at live parts Any unauthorised changes modifications or alterations to the device are forbidden Personnel qualifications People who use this device must have read and understood the instructions especially the Safety chapter Residual risks Warning of electrical voltage There is a risk of a short circuit due to li...

Page 4: ...ant measuring spots to extract material for the CM measurement A max min function is available for the assessment of the measurements The measuring device comes equipped with a selectable display illumination When not in use an automatic switch off saves the battery Device depiction 1 2 3 4 No Designation 1 Sensor 2 Battery compartment with cover 3 Operating elements 4 Display Operating elements 5...

Page 5: ... direct sunlight the storage temperature complies with the values specified in the Technical data Remove the batteries from the device Operation Inserting the batteries Insert the supplied battery before first use Note Make sure that the surface of the device is dry and the device is switched off 1 Open the battery compartment at the rear of the device by sliding down the cover 14 2 Use the batter...

Page 6: ... 1 Press the Lamp button 5 ð The background illumination is activated 2 Press the Lamp button 5 again ð The background illumination is deactivated Switching the device off Info The device automatically switches off after approx 30 seconds of non use Please proceed as follows for manual switch off 1 Press the on off switch 8 ð The device is switched off Dielectric measurements The measuring device ...

Page 7: ...hich then simulates high moisture values Consequently a too high measured value will be displayed If the material to be measured contains metal e g nails screws lines pipes etc and is situated within the sensor s measuring field the measured value skyrockets due to intense reflections From visual inspection it is not always apparent whether there are any electrically conducting substances inside t...

Page 8: ...2 19 EU It states that this device must not be disposed of with the household waste at the end of its life You will find collection points for free return of waste electrical and electronic equipment in your vicinity The addresses can be obtained from your municipality or local administration You can also find out about other return options that apply for many EU countries on the website https hub...

Page 9: ...Trotec GmbH Grebbener Str 7 D 52525 Heinsberg 49 2452 962 400 49 2452 962 200 info trotec com www trotec com ...

Reviews: