moisture indicator BM31

Remove discharged batteries from the device. Batteries
contain materials hazardous to the environment. Dispose
of the batteries according to the national regulations.

Remove the batteries from the device if you will not be
using the device for a longer period of time.

Never short-circuit the supply terminal in the battery
compartment!

Do not swallow batteries! If a battery is swallowed, it can
cause severe internal burns within 2 hours! These burns
can lead to death!

If you think batteries might have been swallowed or
otherwise entered the body, seek medical attention
immediately!

Keep new and used batteries and an open battery
compartment away from children.

Observe the storage and operating conditions (see
Technical data).

Intended use

Only use the device for moisture measurements of wood and
building materials within the measuring range specified in the
technical data.
To use the device for its intended use, only use accessories and
spare parts which have been approved by Trotec.

Foreseeable misuse

Do not use the device in potentially explosive atmospheres, for
measurements in liquids or at live parts.
Any unauthorised changes, modifications or alterations to the
device are forbidden.

Personnel qualifications

People who use this device must:

have read and understood the instructions, especially the
Safety chapter.

Residual risks

Warning of electrical voltage

There is a risk of a short-circuit due to liquids
penetrating the housing!
Do not immerse the device and the accessories in
water. Make sure that no water or other liquids can
enter the housing.

Warning of electrical voltage

Work on the electrical components must only be
carried out by an authorised specialist company!

Warning

Risk of suffocation!
Do not leave the packaging lying around. Children may
use it as a dangerous toy.

Warning

The device is not a toy and does not belong in the
hands of children.

Warning

Dangers can occur at the device when it is used by
untrained people in an unprofessional or improper way!
Observe the personnel qualifications!

Caution

Keep a sufficient distance from heat sources.

Note

To prevent damages to the device, do not expose it to
extreme temperatures, extreme humidity or moisture.

Note

Do not use abrasive cleaners or solvents to clean the
device.

Summary of Contents for 3510205031

Page 1: ...TRT BA BM31 TC220926TTRT02 002 EN BM31 EN ORIGINAL INSTRUCTIONS MOISTURE INDICATOR ...

Page 2: ...vicinity of the device or its site of use Warning Read all safety warnings and all instructions Failure to follow the warnings and instructions may result in electric shock fire and or serious injury Save all warnings and instructions for future reference The device is supplied with warning signs Prior to initial start up make sure to paste the corresponding warning signs in your local language ov...

Page 3: ...ot use the device in potentially explosive atmospheres for measurements in liquids or at live parts Any unauthorised changes modifications or alterations to the device are forbidden Personnel qualifications People who use this device must have read and understood the instructions especially the Safety chapter Residual risks Warning of electrical voltage There is a risk of a short circuit due to li...

Page 4: ...ant measuring spots to extract material for the CM measurement A max min function is available for the assessment of the measurements The measuring device comes equipped with a selectable display illumination When not in use an automatic switch off saves the battery Device depiction 1 2 3 4 No Designation 1 Sensor 2 Battery compartment with cover 3 Operating elements 4 Display Operating elements 5...

Page 5: ... direct sunlight the storage temperature complies with the values specified in the Technical data Remove the batteries from the device Operation Inserting the batteries Insert the supplied battery before first use Note Make sure that the surface of the device is dry and the device is switched off 1 Open the battery compartment at the rear of the device by sliding down the cover 14 2 Use the batter...

Page 6: ... 1 Press the Lamp button 5 ð The background illumination is activated 2 Press the Lamp button 5 again ð The background illumination is deactivated Switching the device off Info The device automatically switches off after approx 30 seconds of non use Please proceed as follows for manual switch off 1 Press the on off switch 8 ð The device is switched off Dielectric measurements The measuring device ...

Page 7: ...hich then simulates high moisture values Consequently a too high measured value will be displayed If the material to be measured contains metal e g nails screws lines pipes etc and is situated within the sensor s measuring field the measured value skyrockets due to intense reflections From visual inspection it is not always apparent whether there are any electrically conducting substances inside t...

Page 8: ...2 19 EU It states that this device must not be disposed of with the household waste at the end of its life You will find collection points for free return of waste electrical and electronic equipment in your vicinity The addresses can be obtained from your municipality or local administration You can also find out about other return options that apply for many EU countries on the website https hub...

Page 9: ...Trotec GmbH Grebbener Str 7 D 52525 Heinsberg 49 2452 962 400 49 2452 962 200 info trotec com www trotec com ...