pyrometer controlled via smartphone BP21WP

Disposal

Always dispose of packing materials in an environmentally
friendly manner and in accordance with the applicable local
disposal regulations.

The icon with the crossed-out waste bin on waste

electrical or electronic equipment stipulates that this equipment
must not be disposed of with the household waste at the end of
its life. You will find collection points for free return of waste
electrical and electronic equipment in your vicinity. The
addresses can be obtained from your municipality or local
administration. You can also find out about other return options
that apply for many EU countries on the website 
https://hub.trotec.com/?id=45090. Otherwise, please contact an
official recycling centre for electronic and electrical equipment
authorised for your country.
The separate collection of waste electrical and electronic
equipment aims to enable the re-use, recycling and other forms
of recovery of waste equipment as well as to prevent negative
effects for the environment and human health caused by the
disposal of hazardous substances potentially contained in the
equipment.

 In the European Union, batteries and accumulators must

not be treated as domestic waste, but must be disposed of
professionally in accordance with Directive 2006/66/EC of the
European Parliament and of the Council of 6 September 2006
on batteries and accumulators. Please dispose of batteries and
accumulators according to the relevant legal requirements.

Only for United Kingdom

According to Waste Electrical and Electronic Equipment
Regulations 2013 (SI 2013/3113) and the Waste Batteries and
Accumulators Regulations 2009 (SI 2009/890), devices that are
no longer usable must be collected separately and disposed of
in an environmentally friendly manner.

Declaration of conformity

We – Trotec GmbH – declare in sole responsibility that the
product designated below was developed, constructed and
produced in compliance with the requirements of the EU Radio
Equipment Directive in the version 2014/53/EU.

Product model/Product:

BP21WP

Product type:

pyrometer controlled via
smartphone

Year of manufacture as of:

2019

Relevant EU directives:

2001/95/EC: 3 December 2001

2014/30/EU: 29/03/2014

Applied harmonised standards:

EN 61326-1:2013

Applied national standards and technical specifications:

EN 300 328 V2.1.1:2016-11

EN 301 489-1 Draft Version 2.2.0:2017-03

EN 301 489-17 Draft Version 3.2.0:2017-03

EN 61010-1:2010

EN 62479:2010

Manufacturer and name of the authorised representative of
the technical documentation:

Trotec GmbH
Grebbener Straße 7, D-52525 Heinsberg
Phone: +49 2452 962-400
E-mail: [email protected]

Place and date of issue:
Heinsberg, 

22.07.2019

Detlef von der Lieck, Managing Director

Summary of Contents for 3510006031

Page 1: ...TRT BA BP21WP TC220325TTRT05 004 EN BP21WP EN OPERATING MANUAL PYROMETER CONTROLLED VIA SMARTPHONE ...

Page 2: ...rting or using the device Always store the manual in the immediate vicinity of the device or its site of use Warning Read all safety warnings and all instructions Failure to follow the warnings and instructions may result in electric shock fire and or serious injury Save all warnings and instructions for future reference Do not use the device in potentially explosive rooms or areas and do not inst...

Page 3: ...f such equipment and cause malfunctions Make sure that no other devices are malfunctioning during the use of your device Any unauthorised changes modifications or alterations to the device are forbidden Personnel qualifications People who use this device must be aware of the dangers that occur when working with laser measuring devices have read and understood the operating manual especially the Sa...

Page 4: ... app the pyrometer permits non contact infrared surface temperature measurements The pyrometer comes equipped with an on demand multi point laser which does not serve for temperature measurements but is instead used as aiming aid for the surface to be measured In case of individual measurements the measurement value display can be refreshed both via the app and by a brief actuation of the measurem...

Page 5: ...ature values reach or fall below the dew point Device depiction BP21WP 1 2 3 4 5 No Designation 1 Measuring sensor 2 LED 3 On off measurement button 4 Battery compartment with cover 5 Lock Technical data Parameter Value Model BP21WP Measuring range 30 C to 250 C 22 F to 482 F Accuracy 3 C at 0 C 2 C 2 at 0 C Resolution 0 1 C 0 1 F Smallest measuring spot ø 12 7 mm distance 254 mm Degree of emissio...

Page 6: ... data Remove the batteries from the device Operation Inserting the batteries Note Make sure that the surface of the device is dry and the device is switched off 1 Unlock the battery compartment by turning the lock 5 in a way that the arrow points towards the opened padlock icon 2 Remove the cover from the battery compartment 4 3 Insert the batteries 3 batteries of type AAA into the battery compart...

Page 7: ...6 No Designation Meaning 6 Sensors button Opens the sensors overview 7 Refresh button Refreshes the list of sensors near the terminal device 8 Connect button Connects the displayed sensor to the terminal device Switching the multi point laser on off 1 Briefly actuate the On off measurement button 3 at the appSensor twice to switch on the multi point laser 2 Briefly actuate the On off measurement b...

Page 8: ...t mode 1 Press the Refresh measured value button 10 on the terminal device ð The appSensor determines the current measured value which is then displayed on the terminal device 2 You can also press the On off measurement button 3 on the appSensor ð The appSensor determines the current measured value which is then displayed on the terminal device Measurement settings Proceed as follows to adjust the...

Page 9: ...7 REC button Opens the context menu for sensors 18 Measurement series indication Indicates the measured values of the measurement series in degrees Celsius Performing an individual spot measurement with image If you have selected individual spot measurement with image you will be prompted to choose whether you want to use a photo already saved in the mobile device s gallery or take a new one direc...

Page 10: ... Indicates the measurement grid of the measuring field grid field to be measured flashes red 22 Measured value data logging button Saves the measured value for the flashing grid field No Designation Meaning 23 UNDO button Deletes the saved measured value for the respective grid field 24 SKIP button Skips the grid field flashing red and moves on to the next grid field 25 NEW COLUMN button Starts a ...

Page 11: ...um and average values for the temperature as well as the current temperature value 17 REC button Opens the context menu for sensors 21 Measuring field with grid Indicates the measurement grid of the measuring field grid field to be measured flashes red 22 Measured value data logging button Saves the measured value for the flashing grid field 23 UNDO button Deletes the saved measured value for the ...

Page 12: ...asured values Discards the recorded measured values 31 Continue button Resumes the recording of the measured values without saving Analysing measurements Proceed as follows to call up the saved measurements 1 Press the MEASUREMENTS button 32 ð An overview of already saved measurements will be displayed 2 Press the Display measurement button 34 for the desired measurement to be indicated ð A contex...

Page 13: ... graphic button Creates a graphic representation of the logged values and saves it as a PNG file 42 Generate image overlay button Combines a background image with the coloured representation of the measured moisture values 43 Colour scaling button Allows you to adjust the colour display of the measured moisture values Generating a report The reports generated in the MultiMeasure Mobile app are sho...

Page 14: ... of the terminal device SENSORS MEASUREMENTS REPORTS CUSTOMERS SETTINGS Customers Add a customer from your address book contacts or enter the details for a new customer 47 48 Info You can perform a new measurement directly from the input mask Calling up customers Proceed as follows to call up an already created customer 1 Press the CUSTOMERS button 47 ð The customers overview opens 2 Press the cor...

Page 15: ...apter Operation Cleaning Clean the device with a soft damp and lint free cloth Make sure that no moisture enters the housing Do not use any sprays solvents alcohol based cleaning agents or abrasive cleaners but only clean water to moisten the cloth Repair Do not modify the device or install any spare parts For repairs or device testing contact the manufacturer Errors and faults The device has been...

Page 16: ...onally in accordance with Directive 2006 66 EC of the European Parliament and of the Council of 6 September 2006 on batteries and accumulators Please dispose of batteries and accumulators according to the relevant legal requirements Only for United Kingdom According to Waste Electrical and Electronic Equipment Regulations 2013 SI 2013 3113 and the Waste Batteries and Accumulators Regulations 2009 ...

Page 17: ...Trotec GmbH Grebbener Str 7 D 52525 Heinsberg 49 2452 962 400 49 2452 962 200 info trotec com www trotec com ...

Reviews: