Information requirements for electrical local space heaters

Parameter

Value / item

Model

PAE 19 H

Heat output

Nominal heat output P

nom

2.0 kW

Minimum heat output (indicative) P

min

1.4 kW

Maximum continuous heat output P

max,c

2.0 kW

Auxiliary electricity consumption

At nominal heat output el

max

NA

At minimum heat output el

min

NA

In standby mode el

sb

0.00022 kW

Type of heat input

Manual heat charge control, with integrated thermostat

NA

Manual heat charge control with room and/or outdoor temperature
feedback

NA

Electronic heat charge control with room and/or outdoor temperature
feedback

NA

Fan assisted heat output

NA

Type of heat output/room temperature control

Single-stage heat output, no room temperature control

NO

Two or more manual stages, no room temperature control

NO

With mechanic thermostat room temperature control

NO

With electronic room temperature control

YES

With electronic room temperature control plus day timer

NO

With electronic room temperature control plus week timer

NO

Other control options

Room temperature control, with presence detection

NO

Room temperature control, with open window detection

NO

With distance control option

NO

With adaptive start control

NO

With working time limitation

YES

With black bulb sensor

NO

Contact details

Trotec GmbH
Grebbener Straße 7
D-52525 Heinsberg

NA = not applicable

Summary of Contents for 1210003006

Page 1: ...TRT BA PAE19H TC220202TTRT01 001 EN PAE 19 H EN OPERATING MANUAL AIR COOLER EN This product is only suitable for well insulated spaces or occasional use...

Page 2: ...ice or its site of use Warning Read all safety warnings and all instructions Failure to follow the warnings and instructions may result in electric shock fire and or serious injury Save all warnings a...

Page 3: ...ank Empty and clean the water tank prior to storage or transport Do not drink the water Health hazard Never leave water in the water tank when the appliance is not in use Make sure that objects in the...

Page 4: ...s museums warehouses and archives libraries call centres and computer rooms Foreseeable misuse Do not place the device on wet or flooded ground Do not place any objects e g clothing on the device Do n...

Page 5: ...o avoid overheating and fire hazards the device must not be covered Warning of electrical voltage Risk of electric shock The device must not come into contact with water otherwise there is a risk of a...

Page 6: ...e room by a fan The heating capacity can be adjusted on two heating levels The discharge direction of the air can be manually adjusted via the ventilation flaps as well as via the optionally selectabl...

Page 7: ...d observe the following storage conditions Store the device in a dry location and protected from frost and heat Store the device in an upright position where it is protected from dust and direct sunli...

Page 8: ...ntrol Warning of electrical voltage Do not touch the battery compartment with wet or damp hands Note Do not use rechargeable batteries Observe the Technical data for start up Please proceed as follows...

Page 9: ...ge the water every 3 days to prevent bacterial growth Info Optionally you can put ice packs into the water tank for additional cooling Observe the following when using the ice packs Put the ice packs...

Page 10: ...only 13 Optionally you can add ice cubes made of drinking water for additional cooling Observe the minimum and maximum filling level at the filling level indicator 14 The water tank must be filled up...

Page 11: ...will be heavily contaminated This could reduce the performance and result in damage to the device Note For an even distribution of water please make sure that the top section of the evaporation filte...

Page 12: ...ing button Switching the air cooling mode on or off No Designation Meaning 28 Night mode LED Illuminated when night mode is activated 29 Air freshening LED Illuminated when air freshening mode is acti...

Page 13: ...ect all 3 fan speeds manually Please proceed as follows to adjust the fan speed 1 Press the Mode button 30 until the Ventilation LED 31 is lit 2 To adjust the fan stage press the Fan speed button 18 u...

Page 14: ...ode and swing function are saved Any activated timer air freshening and the night mode will not be saved in the device Adding water For filling the water tank proceed as described in the Filling the w...

Page 15: ...device is switched on but the heating function is not working Check the room temperature The room thermostat may have switched off because the desired room temperature has been reached Check whether t...

Page 16: ...Test run X Maintenance and care log Device type Device number Maintenance and care interval 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 Clean the water tank Check air inlets and outlets for dirt and forei...

Page 17: ...Protect electrical components from moisture Do not use any aggressive cleaning agents such as cleaning sprays solvents alcohol based or abrasive cleaners to dampen the cloth Cleaning the water tank W...

Page 18: ...tly for otherwise the device cannot be switched back on Cleaning the air filter The air filter has to be cleaned as soon as it is dirty This is brought to light e g by a reduced capacity see chapter E...

Page 19: ...filter 11 and evaporation filter 8 from the device 11 8 2 Dispose of used evaporation filter 8 according to the national regulations 3 Reinsert both the air filter 11 and the new evaporation filter 8...

Page 20: ...and or outdoor temperature feedback NA Fan assisted heat output NA Type of heat output room temperature control Single stage heat output no room temperature control NO Two or more manual stages no ro...

Page 21: ...ctronic equipment aims to enable the re use recycling and other forms of recovery of waste equipment as well as to prevent negative effects for the environment and human health caused by the disposal...

Page 22: ...Trotec GmbH Grebbener Str 7 D 52525 Heinsberg 49 2452 962 400 49 2452 962 200 info trotec com www trotec com...