Trotec 1210003006 Operating Manual Download Page 13

EN

13

air cooler PAE 19 H

Switching the device on

Once you have completely installed the device as described in
the chapter Assembly and start-up, you can switch it on.

1. Press the on/off switch (

6

) into position 

I

.

ð

The device is now in standby mode.

2. Press the 

on/off

 button (

16

).

ð

An acoustic signal is emitted.

ð

The device starts in ventilation mode at fan stage 1.

ð

The 

On

 

17

Ventilation

 (

31

) and 

Fan stage 1

 LEDS (

19

)

are lit.

Setting the operating mode

The device comes with the following operating modes:

Air cooling

Ventilation

Air freshening

Night mode

Heating function

Air cooling

The air cooling mode can be switched on in addition in the
ventilation, air freshening and night mode.
During air cooling the pump is switched on and the water is
distributed over the evaporation filter to cool the circulating air.
Please proceed as follows to activate air cooling:

ü

The water tank (

13

) must be filled up with water at least to

the minimum filling level.

1. Press the 

air cooling

 button (

27

).

ð

The 

air cooling

 LED (

26

) is lit.

ð

The pump starts.

2. Press the 

Fan speed

 button (

18

) to set the desired fan

stage (1 to 3).

3. Press the 

Air cooling

 button (

27

) again if you wish to

switch off the 

air cooling

.

ð

The 

air cooling

 LED (

26

) goes out.

ð

The device continues to run in the previously selected
operating mode with the pump being switched off, the
fan stage is maintained.

Note

When the Air cooling mode is activated, the air and
evaporation filter must not be removed, otherwise the
water from the filter will drip down into the device.

Note

If there is only a small quantity or no water in the water
tank, the Air cooling mode is switched off after 45 s
and an acoustic warning signal is emitted.

Ventilation

In ventilation mode, you can select all 3 fan speeds manually.
Please proceed as follows to adjust the fan speed:

1. Press the 

Mode

 button(

30

) until the 

Ventilation

 LED (

31

) is

lit.

2. To adjust the fan stage, press the 

Fan speed

 button (

18

)

until the LED for the desired 

Fan speed

 (

19

) is lit.

Air freshening

In 

air freshening

 mode, the fan speed increases and decreases

alternately to generate a pleasant, natural air stream.
Please proceed as follows to activate 

air freshening

:

1. Press the 

Mode

 button(

30

) until the 

Air freshening

 LED (

29

)

is lit.

ð

The fan stages are automatically adjusted.

Night mode

In night mode, the device operates using a preset programme
with different fan speeds to generate an air stream that is
adapted to human sleeping habits.
Night mode can be activated in combination with the 3 fan
stages and 

air cooling

.

At fan stage 1, the device runs permanently at this stage.

At fan stage 2, the device automatically switches to fan
stage 1 after an operating time of 30 minutes and keeps
running at this speed.

At fan stage 3, the device automatically switches to fan
stage 2 after an operating time of 30 minutes. After
another 30 minutes, the device automatically switches to
fan stage 1 and runs permanently at this stage.

Proceed as follows to switch on the 

Night mode

:

1. Press the 

Mode

 button (

30

) until the 

Night mode

 LED (

28

)

is illuminated.

2. Press the 

Fan speed

 button (

18

) until the LED for the

desired 

Fan speed

 (

19

) is lit.

Heating function

In the Heating function mode, the device generates a warm air
stream.

1. Press the 

Heating function

 button(

21

) until the LED for the

desired heating level (

20

) is lit.

ð

The device runs on the heating level selected.

2. To switch off the heating function, press the 

Heating

function

 button (

21

) until the LEDs for the heating level (

20

)

go out.

ð

The heating function mode is switched off.

Note

After switch-off, the fan continues running for
approx. 10 seconds to cool down the device and to
prevent overheating.

Summary of Contents for 1210003006

Page 1: ...TRT BA PAE19H TC220202TTRT01 001 EN PAE 19 H EN OPERATING MANUAL AIR COOLER EN This product is only suitable for well insulated spaces or occasional use...

Page 2: ...ice or its site of use Warning Read all safety warnings and all instructions Failure to follow the warnings and instructions may result in electric shock fire and or serious injury Save all warnings a...

Page 3: ...ank Empty and clean the water tank prior to storage or transport Do not drink the water Health hazard Never leave water in the water tank when the appliance is not in use Make sure that objects in the...

Page 4: ...s museums warehouses and archives libraries call centres and computer rooms Foreseeable misuse Do not place the device on wet or flooded ground Do not place any objects e g clothing on the device Do n...

Page 5: ...o avoid overheating and fire hazards the device must not be covered Warning of electrical voltage Risk of electric shock The device must not come into contact with water otherwise there is a risk of a...

Page 6: ...e room by a fan The heating capacity can be adjusted on two heating levels The discharge direction of the air can be manually adjusted via the ventilation flaps as well as via the optionally selectabl...

Page 7: ...d observe the following storage conditions Store the device in a dry location and protected from frost and heat Store the device in an upright position where it is protected from dust and direct sunli...

Page 8: ...ntrol Warning of electrical voltage Do not touch the battery compartment with wet or damp hands Note Do not use rechargeable batteries Observe the Technical data for start up Please proceed as follows...

Page 9: ...ge the water every 3 days to prevent bacterial growth Info Optionally you can put ice packs into the water tank for additional cooling Observe the following when using the ice packs Put the ice packs...

Page 10: ...only 13 Optionally you can add ice cubes made of drinking water for additional cooling Observe the minimum and maximum filling level at the filling level indicator 14 The water tank must be filled up...

Page 11: ...will be heavily contaminated This could reduce the performance and result in damage to the device Note For an even distribution of water please make sure that the top section of the evaporation filte...

Page 12: ...ing button Switching the air cooling mode on or off No Designation Meaning 28 Night mode LED Illuminated when night mode is activated 29 Air freshening LED Illuminated when air freshening mode is acti...

Page 13: ...ect all 3 fan speeds manually Please proceed as follows to adjust the fan speed 1 Press the Mode button 30 until the Ventilation LED 31 is lit 2 To adjust the fan stage press the Fan speed button 18 u...

Page 14: ...ode and swing function are saved Any activated timer air freshening and the night mode will not be saved in the device Adding water For filling the water tank proceed as described in the Filling the w...

Page 15: ...device is switched on but the heating function is not working Check the room temperature The room thermostat may have switched off because the desired room temperature has been reached Check whether t...

Page 16: ...Test run X Maintenance and care log Device type Device number Maintenance and care interval 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 Clean the water tank Check air inlets and outlets for dirt and forei...

Page 17: ...Protect electrical components from moisture Do not use any aggressive cleaning agents such as cleaning sprays solvents alcohol based or abrasive cleaners to dampen the cloth Cleaning the water tank W...

Page 18: ...tly for otherwise the device cannot be switched back on Cleaning the air filter The air filter has to be cleaned as soon as it is dirty This is brought to light e g by a reduced capacity see chapter E...

Page 19: ...filter 11 and evaporation filter 8 from the device 11 8 2 Dispose of used evaporation filter 8 according to the national regulations 3 Reinsert both the air filter 11 and the new evaporation filter 8...

Page 20: ...and or outdoor temperature feedback NA Fan assisted heat output NA Type of heat output room temperature control Single stage heat output no room temperature control NO Two or more manual stages no ro...

Page 21: ...ctronic equipment aims to enable the re use recycling and other forms of recovery of waste equipment as well as to prevent negative effects for the environment and human health caused by the disposal...

Page 22: ...Trotec GmbH Grebbener Str 7 D 52525 Heinsberg 49 2452 962 400 49 2452 962 200 info trotec com www trotec com...