![Trotec 1210003006 Operating Manual Download Page 19](http://html1.mh-extra.com/html/trotec/1210003006/1210003006_operating-manual_1171664019.webp)
EN
19
air cooler PAE 19 H
Replacing the evaporation filter
Note
When set to air cooling mode, the device must not be
operated without the evaporation filter, otherwise
cooling
will not work.
Note
Do not operate the device without an inserted air filter!
Without the air filter, the inside of the device will be
heavily contaminated. This could reduce the
performance and result in damage to the device.
Note
For an even distribution of water please make sure that
the top section of the evaporation filter is positioned at
the top.
The evaporation filter should be replaced in case of heavy
soiling.
In standard operation, the interval for replacing the evaporation
filter is approx. 1 year.
Allow the evaporation filter to dry before removing it from the
device.
1. Remove the air filter (
11
) and evaporation filter (
8
) from the
device.
11
8
2. Dispose of used evaporation filter (
8
) according to the
national regulations.
3. Reinsert both the air filter (
11
) and the new evaporation
filter (
8
) into the device.
11
8
Activities required after maintenance
If you want to continue using the device:
•
Reconnect the device to the mains.
If you do not intend to use the device for a considerable time:
•
Store the device according to the Transport and storage
chapter.
Technical annex
Technical data
Parameter
Value
Evaporation capacity
600 ml/h
Heating capacity
level 1
level 2
1400 W
2000 W
Air flow rate
118 m
3
/h
Mains connection
220 – 240 V / 50 Hz
Nominal current consumption
0.2 A
Power consumption
50 W
Sound pressure level
(distance of 1 m)
55 dB(A)
Water tank capacity
4 l
Weight
6 kg
Dimensions (length x width x
height)
248 x 310 x 684 mm
Minimum distance to walls and
other objects:
top (A):
rear (B):
sides (C):
front (D):
100 cm
100 cm
100 cm
100 cm
Remote control batteries
3V CR2032