Service Instructions
Tropos Mobile Router Installation Guide
14
case, installing and operating the indicator requires knowledge and skill in basic electronics,
wiring, and cable assembly.
Figure 14
is a schematic drawing of the indicator.
Figure 14 Typical Remote Indicator Circuit on Dashboard
Caution
Voltage on pin 9 must always be greater than the voltage at pin 5 (ground). Pin 5 is
electrically connected to the chassis ground (negative ground). Maximum current from
pin 9 to pin 5 is 50mA. Maximum voltage on pin 9 at any time is 32V (the same as for
the router.) Exceeding these maximums can damage the router.
Service Instructions
This section contains service information.
Resetting the Router
To perform a hardware reset of the router, unplug the router, pull the fuse out, or turn off the
vehicle power. Wait 10 seconds and then reconnect the plug, fuse, or vehicle power.
To reset the router configuration to factory defaults, use the Tropos Configuration Utility, as
described in the
Tropos Networks User Guide
.
Router side
0.5A inline
fast-acting fuse
LED
Remote indicator
switch
(internal)
1
5
4
3
2
6
9
7.5A
8
7
R1
Vehicle battery
power
10-32Vdc
1.5K
typical
User DB-9
hood
9