Figure 8 Remote Indicator Schematic
Caution
Voltage on pin 9 must always be greater than the voltage at pin 5 (ground). Pin 5 is
electrically connected to the chassis ground (negative ground). Maximum current from
pin 9 to pin 5 is 50mA. Maximum voltage on pin 9 at any time is 32V (the same as for
the Tropos 4210 router.) Exceeding these maximums can damage the remote indicator.
Service Instructions
This section contains service information for the Tropos 4210 router.
Resetting the Router
To perform a hardware reset of the router, unplug the router, pull the fuse out, or turn off the
vehicle power. Wait 10 seconds and then reconnect the plug, fuse, or vehicle power.