background image

 AMD-53-S2 MODULATOR / MULTIPLEXER

3.11. MODULATOR PARAMETERS 

In this menu you need to specify the parameters of the output carrier

:

Output frequency              up 900 to 2150MHz;
Symbol Rate                     up 1000 to 30000 kSymb per Second
Modulation/FEC                QPSK: 1/3, 2/5, 1/2, 3/5, 2/3, 3/4, 4/5, 5/6, 8/9, 9/10
                                           8PSK: 3/5, 2/3, 3/4, 5/6, 8/9, 9/10
                                           16APSK: 2/3, 3/4, 4/5, 5/6, 8/9, 9/10
                                           32APSK: 3/4, 4/5, 5/6, 8/9, 9/10
Roll-off 

 

 

0,2 ; 0,25 ; 0,35

FEC Frame length   

Normal/short 

Pilot tone 

 

 

On/off

Spectrum Inversion  

On/off 

Output attenuation   

up -31.5 to 0 dB

RF output 

 

 

On/Off

The actual bitrate at the output of the modulator is displayed as a blue scale at the top of the menu.
Free capacity of the transponder is filled with zero packets if the subscription data does not come to 
the modulator from the billing server. The capacity occupied by zero packets is indicated in the form 
of a gray scale.

Free capacity is filled with subscription packages if the billing server sends TROPHY-ACCESS CAS 
data to the modulator. The efficiency of data transmission is maximum. The capacity that the 
subscription data occupies is indicated in the form of a yellow scale. Thanks to this technology, the 
CAS data transmission efficiency is maximum.  

 

 

Payload rate: 30,155 Mbit (0,94%)                                 

Subs rate: 1,93 Mb                                 

Payload rate: 30,155 Mbit (0,94%)                                 

Subs rate: 0 Mb                                 

Payload rate: 30,155 Mbit (0,94%)                                 

Subs rate: 1,93 Mb                                 

INSTRUCTION MANUAL

13

Summary of Contents for AMD-53-S2

Page 1: ...INSTRUCTION MANUAL AMD 53 S2 DVB S2 MODULATOR 120 CHANNEL MULTIPLEXER Part No 1001 1008 Instruction Manual AMD 53 S2 MODULATOR MULTIPLEXER ...

Page 2: ...INSTRUCTIONS 4 3 1 SAFETY INSTRUCTIONS 4 3 2 GENERAL DESCRIPTION OF FUNCTIONS 4 3 3 MULTIPLEXER REMULTIPLEXER PID FILTER 4 3 4 INSTALLING FUNCTIONAL ELEMENTS AND FACTORY SETTINGS 5 3 5 SETTINGS FOR THE ETHERNET NETWORK INTERFACE 6 3 6 CONFIGURATIONS VIA THE ETHERNET INTERFACE 7 3 7 CONNECTION SETUP 7 3 8 INPUTS 9 3 9 PROGRAMS 10 3 10 SI GENERATOR 11 3 11 MODULATOR PARAMETERS 12 4 SPECIFICATIONS 13...

Page 3: ...version into L band range 950 2150MHz Ahigh speed digital analogue converter DAC is responsible for the excellent output signal 1 1 MAIN FUNCTIONS OFAMD 53 S2 MODULATOR MULTIPLEXER covers the full L Band range 950 2150 MHz or IF Band range 70 140 MHz optional and offers bit rate from 2 Mbps up to 100 Mbps provides up to 120 independent multiplexed MPEG transport streams to a single carrier with bu...

Page 4: ...remaping and PCR correction WEB interface also offers monitoring of all input streams AMD 53 S2 MODULATOR MULTIPLEXER integrates the core technology required to perform high quality modulation based on TROPHY expertise It provides customers with a best in class performance providing a high SNR value excellent shoulder levels and lowest phase noise 2 ASI input Demux Mux WEB control TS input 1Gb Eth...

Page 5: ... Billing data are fed to theAMD 53 S2 MODULATOR MUX over Ethernet or ASI 2 TROPHY ACCESS CAS Options Type of CAS Polynomial length The size of the decoder address field Quantity of addressable decoders The number of serviced channels The number of packets serviced Automatic disconnection of the decoder Individual addressable message Cardless doesn t match CSA algorithm 2048 bits 32 bits 4 294 967 ...

Page 6: ...e operating parameters can be varied within wide limits Deliveries are made with the following configurations device versions Up to 120 input elementary transport streams are multiplexed at device and inserted into the output DVB S2 carrier with maximum bit rate of 100 Mbps and is transmitted via the N type connector The output signal contains all the tables necessary to the program and associated...

Page 7: ...n Input mode IP MUX Scrambler Enabled Part No 1001 1003 1005 1007 Disabled Part No 1002 1004 1006 1008 Billing Server PSR Restamping Enabled Inputs section Protocol Port UNICAST UDP 1234 SI generator section Provider name no name Transport Stream ID 2 Original Network ID 4 TDT generator ON Auxiliary SI Port 901 Modulator section Output Frequency MHZ 1000 Symbol Rate kSpS 14400 Modulation FEC 8PSK ...

Page 8: ...xploitation of a gateway in the network SNMPTrap IP Addr 0 0 0 0 255 255 255 255 IPaddress to a possible used SNMPtrap manager Network Time Protocol NTP is a networking protocol for clock synchronization between computer systems over IP NTP is intended to synchronize all participating computers to Coordinated Universal Time UTC You must specify the URLof NTP Server that will synchronize the curren...

Page 9: ...ice from a PC the PC has to be in the 255 255 255 0 subnet If multiple devices are connected to the same network each device must be set to its own unique IP address to avoid address conflicts After these settings the IP address of the PC has to be adjusted to match the network 3 7 CONNECTION SETUP When the IP address for the device has been entered into the address field of the browser a connecti...

Page 10: ...TAMPING PCR Program Clock Reference Synchronization of the receiver System Time Clock STC with the transmitter STC depends on transmitting PCRs through a constant delay portion of the system Thus PCRs are inserted following the encoder buffer and extracted before the receiver buffer PCRs are inserted with a maximum interval of 100ms Synchronization can be adversely affected by transmission over li...

Page 11: ...e source of the transport stream has been connected to the ETHERNET switch of the local network you must press the button and enter the port number of source The information about the number of programs found on a specific port is displayed in the Programs column In the event that there is no correct transport stream on any port the icon with a rotating scale is displayed in the Programs column Ch...

Page 12: ...XER 3 8 2 IP MUX mode with DEMUX MUX processing The data enters the modulator via preliminary processing In this mode data is received from one or several ports Unicast packets receiving Multicast packets receiving INSTRUCTION MANUAL ...

Page 13: ...own VPID and PCR PID has a same value You can change CONDITIONAL ACCESS mode also FTA Type1 Type2 Type3 The multiplex contains a number of different services where each service contains at least one audio stream at least one video stream and usually several data streams You must to indicate the type of the stream some can t be identified by the software in this case and the SID number that is the ...

Page 14: ... a server name that will synchronize the current time in the NETWORK menu see page No 6 If this option is not available you must set OFF value in theTDTGENERATION line In multiplexer mode the device automatically generates the following service tables ProgramAssociation table PAT defined by the MPEG standard The ProgramAssociation Table is the fundamental table for service information It describes...

Page 15: ...displayed as a blue scale at the top of the menu Free capacity of the transponder is filled with zero packets if the subscription data does not come to the modulator from the billing server The capacity occupied by zero packets is indicated in the form of a gray scale Free capacity is filled with subscription packages if the billing server sends TROPHY ACCESS CAS data to the modulator The efficien...

Page 16: ...Attenuation range Monitoring RF output 20dB AMD 53 S2 MODULATOR MULTIPLEXER ETSI 103 129 EN 302 307 EN 301 210 EN50083 9 ETSI TR 101 891 ETSI TS 102 034 EN 300 468 EN 50083 9 MPEG TS 188 bytes over ASI 200 880 mV 2 100 Mbps continous burst BNC socket 75 Ohm Ethernet 10 100 1000 Base T RJ 45 UDP Unicast Multicast CBR VBR TROPHY ACCESS additional license 900MHz to 2150MHz 10kHz step 50MHz to 90MHz 1...

Page 17: ... 3 5 2 3 3 4 4 5 5 6 8 9 9 10 8PSK 3 5 2 3 3 4 5 6 8 9 9 10 16APSK 2 3 3 4 4 5 5 6 8 9 9 10 32APSK 3 4 4 5 5 6 8 9 9 10 CCM Constant Coding and Modulation VCM Variable Coding and Modulation SeamlessACM Adaptive Coding and Modulation Short 16200 Normal 64800 On or Off From 1 to 30Mbaud step 1Baud Web Browser Control Monitoring 10 100 1000 Base T Ethernet ports 90 to 240VAC 50Hz 15W 2kg Weight 0 C t...

Reviews: