background image

 

Installation Guide ROQSTAR 
Document no. 130- 106.44  11/2017 ENG 

 

Page 5 of 16

 

1.3. 

Qualified Personnel 

The  user  must  ensure  that  only  qualified  personnel  will  work  with  the  device.  The  product/system 
described  in  this  documentation  may  be  operated  only  by  personnel  qualified  for  the  specific  task  in 
accordance  with the relevant documentation, in particular  its  warning  notices and safety  instructions. 
Qualified personnel are those who, based on their training and experience, are capable of identifying 
risks and avoiding potential hazards when working with these products/systems. 
 

1.4. 

Intended use 

Proper  transport,  storage,  installation,  assembly,  commissioning,  operation  and  maintenance  are 
required to ensure that TRONTEQ products operate safely and without any problems. The permissible 
ambient  conditions  must  be  complied  with.  The  information  in  the  relevant  documentation  must  be 
observed. 

1.5. 

Liability Limitation 

All  information  and  instructions  in  this  operating  instruction  has  been  compiled  in  accordance  with 
current  standards  and  regulations,  state  of  the  art  as  well  as  the  knowledge  and  experience  of  the 
applications in the field. In the following cases the manufacturer is not liable for damages: 
 

►  Disregard of the operating instructions in this manual. 

►  Improper use.  

►  Employment of non-qualified personnel. 

►  Unauthorized technical modification or reconstruction. 

►  Use of other connectors as delivered. 

 
The general terms and conditions are valid as well as the delivery terms of the manufacturer and the 
legal regulations which were taken when the contract was concluded. 
 
We  have  reviewed  the  contents  of  this  publication  to  ensure  consistency  with  the  hardware  and 
software  described.  Since  variance  cannot  be  precluded  entirely,  we  cannot  guarantee  full 
consistency.  However,  the  information  in  this  publication  is  reviewed  regularly  and  any  necessary 
corrections are included in subsequent editions. 

1.6. 

Disposal 

The device should be disposed of after use in accordance with the current disposal regulations as 
electronic waste. 
 

 

Summary of Contents for ROQSTAR

Page 1: ...stallation Guide ROQSTAR Document no 130 106 44 11 2017 ENG Page 1 of 16 Installation Guide Industrial Ethernet Switch with PoE ROQSTAR Artikel Nr 006 130 106 130 106 44 11 2017 ENG 130 106 44 112017 ENG ...

Page 2: ...lowed as part of use of TRONTEQ products Any other use which goes beyond in particular copying reproduction translation requires written consent of TRONTEQ Electronic TRONTEQ Electronic reserves the right to modify the contents of this manual In addition we refer to the conditions of use specified in the license agreement The latest version of this manual is available online at www tronteq de ...

Page 3: ... 3 Connection of Ethernet ports 8 4 First start up 8 4 1 Default settings 8 5 PoE operation 8 5 1 General 8 5 2 Power budgeting 8 6 LED Display 9 6 1 System status LED 9 6 2 Ethernet port LED 9 6 3 PoE status LED 9 7 Technical data 10 7 1 Electrical 10 7 2 Mechanical 11 7 3 Environment 11 7 4 Standards and approvals 11 8 Wiring diagrams 12 8 1 Power cable 12 8 2 Ethernet M12 to RJ45 cable 12 8 3 E...

Page 4: ...ction are provided for basic understanding and may differ from the actual design 1 2 Warning information system This manual contains notices you have to observe in order to ensure your personal safety as well as to prevent damage to property The notices referring to your personal safety are highlighted in the manual by a safety alert symbol notices referring only to property damage have no safety ...

Page 5: ... All information and instructions in this operating instruction has been compiled in accordance with current standards and regulations state of the art as well as the knowledge and experience of the applications in the field In the following cases the manufacturer is not liable for damages Disregard of the operating instructions in this manual Improper use Employment of non qualified personnel Una...

Page 6: ...vides a total power supply of 60W for all connected PD Powered Devices PoE PoE PD devices are supported The ROQSTAR PoE Switch is robust has a high reliability and can be deployed in a wide range of applications such as CCTV and camera on vehicles or decentralized machine automation 2 2 Interfaces Here is an example of the ROQSTAR Switch the image can differ depending on variants Digit Description...

Page 7: ...orm the following steps for mounting the device Make sure that all electrical connectors are volt free Make sure that the device is disconnected from all connections Prepare the drill holes at the installation site Mount the device on a flat surface with four M4 screws Ground the device via the provided ground connection Make sure that the ground connection is always tightened securely Use toothed...

Page 8: ...unction is available on each port As soon as a PD is connected and registered the PoE voltage is activated at that port 5 PoE operation 5 1 General The PoE function is avaible about 10 seconds after the operating voltage is activated at V1 The Switch provides a total power output of 60W The PoE total power output is monitored by the Switch The PoE voltage is 53V Is a PD succesfully registered then...

Page 9: ...ff power supply V2 is not connected green lights up power supply V2 is connected 6 2 Ethernet port LED LED Color Activity Operating state L A off no network connection Link Down green lights up network connection with 10 Mbit s or 100 Mbit s Link Up green blinks data traffic 6 3 PoE status LED LED Color Activity Operating state PoE off PoE voltage is not ativated yellow lights up PoE voltage is ac...

Page 10: ... 52V 80 80 80 W W W Immunity of power interruption 10 ms Internal fuse 2A T Internal fuse PoE 7A T Ethernet Ports min typ max Dimension Switch architecture Store and Forward Bitrate 10 100 Mbit s Output resistance 100 Input resistance 100 Latency at 90 load at 100 Mbit s frame size 64 1518 Byte at 10 Mbit s frame size 64 1518 Byte 8 125 8 125 9 133 9 133 µs µs Throughput unicast packets Frame size...

Page 11: ...4 screws 7 3 Environment Parameter min typ max Dimension Ambient temperature during operation durable 15min 40 40 70 85 C C Ambient temperature storage 40 85 C Humidity not condensing 10 95 Air pressure during operation 690 3000 m over NN hPa 7 4 Standards and approvals The device is compliant with the following test standard Electromagnetic radiation EN61000 6 4 EN55022 Class A FCC47 CFR Part 15 ...

Page 12: ... 8 1 Power cable Connector Diagram Pin assigment 1 brown V1 2 white V2 4 black Fault 3 blue Fault 5 yellow green GND for accessories Order No 006 000 003 or 006 000 004 8 2 Ethernet M12 to RJ45 cable M12 connector Diagram RJ45 connector 8 3 Ethernet M12 to M12 cable Connector Diagram Connector ...

Page 13: ...ch 006 130 103 ROQ 08F S LV IP54 10 Port Fast Ethernet Security Managed M12 Switch 006 130 104 ROQ 08F E LV IP54 8 Port Fast Ethernet Expandable M12 Switch 006 130 106 ROQ 08F E LP IP54 8 Port Fast Ethernet Unmanaged M12 PoE Switch 9 2 Accessories Order No Description 006 000 003 M12 power supply cable for ROQSTAR Switches 2m straight 006 000 004 M12 power supply cable for ROQSTAR Switches 2m angl...

Page 14: ...tions regarding our products 10 2 Technical support Please contact our support team at support tronteq de if you have any technical questions or if you need technical training 10 3 Specific product variants You have a specific problem and you need a product variant that doesn t exist today Please contact us for customer specific adaption of our product Please visit us at www tronteq de ...

Page 15: ...Installation Guide ROQSTAR Document no 130 106 44 11 2017 ENG Page 15 of 16 ...

Page 16: ...Installation Guide ROQSTAR Document no 130 106 44 11 2017 ENG Page 16 of 16 TRONTEQ Electronic Siemensstrasse 22 72766 Reutlingen www tronteq de ...

Reviews: