Isolation
Parameter
min.
typ.
max.
Dimension
Ethernet Port
↔ Ethernet Port
-
-
-
VDC
Ethernet Ports (PoE)
↔ V1, V2
± 2250
-
-
VDC
Ethernet Ports
↔ housing (ground)
± 2250
-
-
VDC
housing (ground)
↔ V1, V2
± 850
-
-
VDC
7.2.
Mechanical
Parameter
typ.
Dimension
Dimensions (H x B x T, ± 0,5 mm)
121 x 175 x 52
mm
Mass net
530
g
Housing protection class
IP54
-
Mounting
drilled hole for four M4 screws
-
7.3.
Environment
Parameter
min.
typ.
max.
Dimension
Ambient temperature during operation
durable
15min
-40
-40
-
-
+70
+85
°C
°C
Ambient temperature storage
-40
-
+85
°C
Humidity (not condensing)
10
-
95
%
Air pressure during operation
690
(3000 m
over NN)
-
-
hPa
7.4.
Standards and approvals
The device is compliant with the following test standard.
► Electromagnetic radiation:
► EN61000-6-4
► EN55022: Class A
► FCC47 CFR Part 15 Class A
► Immunity against conducted interference and external fields:
► EN61000-6-2
► EN61000-4-2
► EN61000-4-3
► EN61000-4-4
► EN61000-4-5
► EN61000-4-6
► Specific applications
► EN50155
► EN50121-4
► EN61131-2
► UNECE (E1) R10
► UNECE (E1) R118