background image

 

Installation Guide ROQSTAR  
Document no. 130-103.44 11/2016 ENG 

 

Seite 12 von 16

 

6.4. 

Standards and approvals 

 
The device is compliant with the following test standard.   
 
►  Electromagnetic radiation: 

►  EN61000-6-4 
►  EN55022: Class A 
►  FCC47 CFR Part 15 Class A 
 

►  Immunity against conducted interference and external fields: 

►  EN61000-6-2 
►  EN61000-4-2  
►  EN61000-4-3  
►  EN61000-4-4  
►  EN61000-4-5  
►  EN61000-4-6  

 
►  Specific applications 

►  EN50155 
►  EN50121-4 
►  EN61131-2  
►  UNECE (E1) R10 
►  UNECE (E1) R118 

 
 
 
 

 

Summary of Contents for ROQ-08F-E-LV-IP54:ROQ-08F-S-LV-IP54

Page 1: ...cument no 130 103 44 11 2016 ENG Seite 1 von 16 Installation Guide Industrial Ethernet Switch ROQSTAR Order no 006 130 100 Order no 006 130 101 Order no 006 130 102 Order no 006 130 104 130 10X 44 11 2016 ENG 130 103 44 112016 ENG ...

Page 2: ...llowed as part of use of TRONTEQ products Any other use which goes beyond in particular copying reproduction translation requires written consent of TRONTEQ Electronic TRONTEQ Electronic reserves the right to modify the contents of this manual In addition we refer to the conditions of use specified in the license agreement The latest version of this manual is available online at www tronteq de ...

Page 3: ...ply and fault contact 8 3 3 Connection of USB port 8 3 4 Connection of Ethernet ports 8 4 First start up 8 4 1 Default Settings 8 4 2 Configuration 9 5 LED Display 9 5 1 System status LED 9 5 2 Ethernet port LEDs 10 6 Technical data 10 6 1 Electrical 10 6 2 Mechanical 11 6 3 Environment 11 6 4 Standards and approvals 12 7 Wiring diagrams 13 7 1 Power cable 13 7 2 M12 to USB adapter 13 7 3 Ethernet...

Page 4: ...uction are provided for basic understanding and may differ from the actual design 1 2 Warning information system This manual contains notices you have to observe in order to ensure your personal safety as well as to prevent damage to property The notices referring to your personal safety are highlighted in the manual by a safety alert symbol notices referring only to property damage have no safety...

Page 5: ...n All information and instructions in this operating instruction has been compiled in accordance with current standards and regulations state of the art as well as the knowledge and experience of the applications in the field In the following cases the manufacturer is not liable for damages Disregard of the operating instructions in this manual Improper use Employment of non qualified personnel Un...

Page 6: ...ch are equipped with managed software and are configurable through the integrated web interface 2 2 Interfaces Digit Description 1 System LEDs for Orderl Nr 006 130 100 V1 power supply 1 V2 Power Supply 2 for Order Nr 006 130 101 006 130 102 006 130 104 PWR Power MOD Mode ERR Error 2 Power Port with Fault Contact 3 USB Port only for Order Nr 006 130 101 006 130 102 006 130 104 4 Ethernet Port 5 Et...

Page 7: ...form the following steps for mounting the device Make sure that all electrical connectors are volt free Make sure that the device is disconnected from all connections Prepare the drill holes at the installation site Mount the device on a flat surface with four M4 screws Ground the device via the provided ground connection Make sure that the ground connection is always tightened securely Use toothe...

Page 8: ... application 5 GND USB power supply negative pole 3 4 Connection of Ethernet ports Pin Belegung Anschluss Skizze 1 TD Transmit Data 2 RD Receive Data 3 TD Transmit Data 4 RD Receive Data 4 First start up 4 1 Default Settings Order no 006 130 100 The devices with the Order Nr 006 130 100 are unmanaged Switches therefore no configuration can be made After wiring the power supply connection the Switc...

Page 9: ... Activity Operating state V1 aus power supply V1 is not connected green lights up power supply V1 is connected V2 off power supply V2 is not connected green lights up power supply V2 is connected Order no 006 130 101 102 104 LED Colour Activity Operating state PWR off Power supply is not connected green lights up Power supply is connected device is supplied with power green flashes with 1Hz Indica...

Page 10: ...eset level V1 V2 8 0 VDC Current consumption full load all ports V1 V2 9 6V V1 V2 24V V1 V2 60V 380 161 79 418 186 88 mA mA mA Peak inrush current 1ms 10 9 6V 14 60V A Input V1 V2 9 6V V1 V2 24V V1 V2 60V 3 6 3 9 4 7 4 0 4 5 5 3 W W W Bridging of power outage 10 ms Internal fuse 2A T Ethernet Ports min typ max Dimension Switch architecture Store and Forward Bitrate 10 100 Mbit s Output resistance ...

Page 11: ...ng grounding 2250 VDC Fault contact V1 V2 USB housing 1500 VDC Housing grounding V1 V2 USB 850 VDC 6 2 Mechanical Parameter typ Dimension Dimensions H x B x T 0 5 mm 121 x 175 x 52 mm Mass net 530 g Housing protection class IP54 Mounting drilled hole for four M4 screws 6 3 Environment Parameter min typ max Dimension Ambient temperature during operation durable 15min 40 40 70 85 C C Ambient tempera...

Page 12: ...iant with the following test standard Electromagnetic radiation EN61000 6 4 EN55022 Class A FCC47 CFR Part 15 Class A Immunity against conducted interference and external fields EN61000 6 2 EN61000 4 2 EN61000 4 3 EN61000 4 4 EN61000 4 5 EN61000 4 6 Specific applications EN50155 EN50121 4 EN61131 2 UNECE E1 R10 UNECE E1 R118 ...

Page 13: ...iagram Pin assigment 1 brown V1 2 white V2 4 black Fault 3 blue Fault 5 yellow green GND for accessories Order No 006 000 003 or 006 000 004 7 2 M12 to USB adapter M12 Connector Diagram USB Connector 7 3 Ethernet M12 to RJ45 cable M12 connector Diagram RJ45 connector 7 4 Ethernet M12 to M12 cable Connector Diagram Connector ...

Page 14: ...thernet Full Managed M12 Switch 006 130 104 ROQ 08F E LV IP54 8 Port Fast Ethernet Expandable M12 Switch 006 130 103 ROQ 08F S LV IP54 10 Port Fast Ethernet Security Managed M12 Switch not in this document 8 2 Accessories Order No Description 006 000 003 M12 power supply cable for ROQSTAR Switches 2m straight 006 000 004 M12 power supply cable for ROQSTAR Switches 2m angled 006 000 042 Ethernet ca...

Page 15: ...at our support team at support tronteq de if you have any technical questions or if you need technical training 9 2 Specific product variants You have a specific problem and you need a product variant that doesn t exist today Please contact us for customer specific adaption of our product Please visit us at www tronteq de ...

Page 16: ...Installation Guide ROQSTAR Document no 130 103 44 11 2016 ENG Seite 16 von 16 TRONTEQ Electronic Siemensstraße 22 72766 Reutlingen www tronteq de ...