16 P5536.1600 rev A
Carbon Dioxide/Methane Gases • Infrared sensor
The sensor is highly specific to the selected gas and exhibits
consistent sensing accuracy with superior long-term stability.
The linear response means that it can be calibrated for low gas
concentrations and high concentrations up to 100% by volume.
TX6350
.243
.245
.242
.253
.278
.279
Methane
CH
4
Methane
CH
4
Methane
CH
4
Carbon
Dioxide
CO
2
Carbon
Dioxide
CO
2
Carbon
Dioxide
CO
2
Sensing element
Infrared
Sensing range
0 to
5% v/v
0 to
100% LEL
0 to
100% v/v
0 to
2% v/v
0 to
5% v/v
0 to
100% v/v
Zero drift
±0.05% v/v
per month
±1% LEL
per month
±0.5% v/v
per month
±0.05% v/v per
month
±1%
v/v per
month
Repeatability
±0.1% v/v
±2% LEL
±2% v/v
±0.05% v/v
±2% v/v
Response time
T63%
<15 secs
Response time
T90%
<30 secs
Operating life
<5 years
Relative
humidity
15 to 90% non-condensing
Operating
temperature
-10 to +40°C
GENERAL
alarm
1.25% v/v
10% LEL
25% v/v
0.5% v/v
1.25% v/v
25% v/v
HIGH alarm
2.5% v/v
20% LEL
50% v/v
1 % v/v
2.5% v/v
50% v/v
www.trolex.com
Summary of Contents for TX6351
Page 1: ......
Page 2: ......
Page 6: ...6 P5536 1600 rev A 1 4 Dimensions www trolex com...
Page 30: ...30 P5536 1600 rev A 4 Setup and Calibration 4 1 Controls and Indicators www trolex com...
Page 31: ...TX6351 TX6352 User Manual P5536 1600 rev A 31 www trolex com...
Page 55: ......
Page 56: ......
Page 57: ......
Page 58: ......