OVERVIE
W
Sample valve:
Allows for sampling of raw water.
Shut-off valve:
Required to allow maintenance of pre-treatment equipment.
Pre-treatment (illustrative only):
For the UV system to operate effectively, the water should meet certain
water quality parameters, as outlined below. To meet these, pre-treatment of the water may be required.
Pre-treatment equipment must be installed BEFORE the UV chamber. Pre-treatment systems can be
comprised of one or more of the following elements: sediment filters; carbon filters; iron removal systems;
water softeners; cyst reduction filters, etc.
Water Quality Requirements:
Iron:
< .3 PPM (.3 mg/L)
Hardness:
< 120 PPM (7 Grains Per Gallon)
% UVT:
> 75%
1
2
3
4
5
Shut-off valve:
Required to allow maintenance of UV system.
Sample valve:
Allows for sampling of water entering UV chamber; necessary in order to confirm water
being treated is of adequate quality.
UV chamber:
Provides disinfection of the water. MUST BE INSTALLED VERTICALLY.
Sensor:
Optional item that monitors UV output to ensure proper dose (UV exposure) is being provided.
Unique test function allows verification of sensor operation.
Plug Kit:
A stopper for the chamber opening created for a sensor when no sensor is in use.
CoolTouch
TM
fan:
Removes excess heat from stagnant water in chamber during periods without water flow.
Sample valve:
Allows for verification of sampling of water immediately following UV treatment; necessary in
order to confirm proper operation of UV system.
Solenoid valve:
Optional piece of equipment supplied by Trojan. Allows water supply to be shut-off when
proper disinfection cannot be assured. Manual by-pass allows for disinfection of water lines using chlorine
bleach, following installation and maintenance procedures.
Note: If the ground from the electrical panel is tied to the copper water lines, the use of a solenoid valve will require
the installation of an approved ground strap to connect the two lines that have been cut in order to maintain continuity.
Check your local electrical code for the correct clamp and cable size.
Shut-off valve:
Required to allow maintenance of UV system.
Power supply:
Powers and controls the UV lamp and other devices. Provides human interface, displaying
information and allowing control inputs (such as muting the audible alarm).
Power source:
Provides power to the power supply. For safety reasons the outlet must be protected by
a Ground Fault Circuit Interrupter (GFCI). NOTE: to protect the power supply, a UL1449 certified (or
equivalent) transient voltage surge suppressor is recommended.
6
7
8
9
10
11
13
12
14
IMPORTANT:
A 5 micron (nominal) sediment filter must be installed
before the UV system and after any water softening equipment