![Trojan TrojanUVMax G Owner'S Manual Download Page 5](http://html1.mh-extra.com/html/trojan/trojanuvmax-g/trojanuvmax-g_owners-manual_1171006005.webp)
INST
ALLA
TIO
N
WARRANT
Y
MAINTENANC
E
OPERA
TIO
N
OVERVIE
W
SPECIFICATIONS
Operating Parameters
Maximum operating pressure
100 PSI (689 kPa)
Minimum operating pressure
10 PSI (69 kPa)
Maximum ambient air temperature
104
0
F (40
0
C)
Minimum ambient air temperature
32
0
F (0
0
C)
Maximum humidity
100%
Maximum hardness
120 ppm
(7 grains per gallon)
Maximum iron
0.3 ppm
Minimum UVT
75%
Installation
Vertical
Other
Chamber material
316L SST
Rated service life of lamp
2 years
Inlet and outlet
Combo
1
1
/
4
" NPT, 1" FNPT
General (All Models)
Rated flow
dose of
30 mJ/cm
2
--
--
--
up to 19 GPM*
(72 LPM)
20 - 39 GPM*
(76 - 148 LPM)
40 - 45 GPM*
(151 - 170 LPM)
Rated flow
dose of
40 mJ/cm
2
10 GPM
(38 LPM)
20 GPM
(76 LPM)
30 GPM
(114 LPM)
up to 15 GPM*
(57 LMP)
16 - 29 GPM*
(61 - 110 LPM)
30 - 44 GPM*
(114 - 167 LPM)
Electrical
Voltage
120-240V AC
120-240V AC
120-240V AC 120-240V AC
120-240V AC
120-240V AC
Frequency
50-60Hz
50-60Hz
50-60Hz
50-60Hz
50-60Hz
50-60Hz
Max. current
1.2 Amp
1.6 Amp
2.4 Amp
1.2 Amp
1.6 Amp
2.4 Amp
Max. power
consumption
120 Watts
160 Watts
230 Watts
120 Watts
160 Watts
230 Watts
Lamp power
consumption
100 Watts
140 Watts
200 Watts
100 Watts
140 Watts
200 Watts
Pro10
Pro20
Pro30
G+, G
H+, H
J+, J
*Flow rates shown are at 85% UVT.
5