AWC7813 motion controller user manual
WWW.SZTROCEN.COM
82
Figure3-22-2 blank distance
Assuming that the cutting graphic is a circle, the cutting frame graphic is a red
rectangle. If the
【
Blanks Distance
】
is set to 5mm, the cutting frame graphic is a blue
rectangle, that is, the distance from the actual cutting frame position is 5mm.
Supplement: The difference between Run box and cut box
Same: Both follow the same path.
Difference: The former laser head does not emit light, while the latter laser
head emits light. The main purpose of walking the frame is to test the position and
size of the graphic on the material, and the purpose of cutting the frame is to cut off
the outer frame of the graphic.
3.23 Axis Reset
During debugging, a certain axis can be reset separately to make the laser head
return to the X-, Y-, or Z-limit switch positions. Procedure as follows:
In
interface, click
【
More
】→【
Reset
】→【
X&Y Reset
】
/
【
Z Reset
】
to operate.
5mm