![Trocen AWC708S User Manual Download Page 91](http://html1.mh-extra.com/html/trocen/awc708s/awc708s_user-manual_1170758091.webp)
AWC708S Motion Control User Manual
WWW.SZTROCEN.COM
90
Figure 3-2 Delta A Series Low Speed Pulse Wiring Diagram
PIN
43
41
36
37
Signal
PULSE
/PULSE
SIGN
/SIGN
Signal
DIR
PUL
DC 5V
PIN
1
2
3
Delta ASD-A 50P
Interface
AWC708S Servo Control
Interface
Table3-1 Delta ASD-A Series Basic Setting Parameters
Mode
Value
Instruction
P1-00
1102H
Position control mode, negative logic: “Pulse +
Direction”.
Set the parameter to “1102H” to open the high-speed
differential signal, and the maximum pulse frequency is
4Mpps;
Set the parameter to “0102H” low-speed pulse signal,
and the maximum pulse frequency is 500K.
P1-01
00
Select the location mode controlled by the external
instruction.
P2-10
101
DI1 is set to SON servo enablement, and the logic is