![Triumf 24952 Manual Download Page 21](http://html1.mh-extra.com/html/triumf/24952/24952_manual_1169564021.webp)
5 Thread tapping M10x1
Note: thread cutting done by hand not electrically.
Extra long tap M10x1 can be used directly in the drilled hole without additional activities.
Slide guide sleeve over the long tap, ensuring tap alignment and hole where we need to cut
thread. Cut the thread, if possible.
5.1 Dismantle the middle part of drilling mechanism (see Chapter 3, Fig. 17-18). Remove
drilling tip no 6.
5.2 During drilling and tapping process is necessary to blow the hole out of metal chips with
compressed air or suction device (not included in this set.
For thread cutting, install middle part of the mechanism with long tap M10x1 and guide No.7
(Figure 33).
5.3
Dismantle drilling mechanism in the back order of its assembly. Check the cleaness of the
injector stud hole. After detaching drilling mechanism and before stud installing can be thread
more cutted if necessary.
5.4 Install a new stud in classic way. Secure stud against his unscrewing with thread retainer
no. 14 (included in kit). Screw nut and washers to installed stud (included in the kit).
6 Stud installation
After thread is tapped, clean hole from chips, clean also the new stud (available separately
order number 35069) with brake cleaner.
6.1 Do not forget:
Clean the hole from buckles and other debris
Clean the hole with brake cleaner
Apply glue – bolt retainer to stud. Screw the stud.
Install stud into the cleaned and degreased hole. Tight stud in clockwise.
Picture 33.
Tapping process M10x1