Triton WALLY-OK7Q User Manual Download Page 5

                                                                                                                                                                      XM894-V1.0-NR 

If the device has been exposed to temperature changes due to environmental changes, do not 
switch it on immediately. The arising condensation could damage the device. Leave the device 
switched off until it has reached room temperature. 
 
This device falls under protection-class I. Therefore it is essential that the device be earthed. 
If protection screen,lens or ultraviolet screen in the fixture is apparently damaged or is damaged 
to exceed their own effective degree, such as cracked and gashed, it must be replaced. 
 
The electric connection must carry out by qualified person. 
 
Make sure that the available voltage is not higher than stated at the end of this manual. 
 
Make sure the power cord is never crimped or damaged by sharp edges. If this would be the case, 
replacement of the cable must be done by an authorized dealer. 
 
Always disconnect from the mains, when the device is not in use or before cleaning it. Only 
handle the power cord by the plug. Never pull out the plug by tugging the power cord. 
 
During initial start-up some smoke or smell may arise. This is a normal process and does not 
necessarily mean that the device is defective, it should decrease gradually. 
 
Please don't project the beam onto combustible substances. 

 

If the external flexible cable or cord of this luminaire is damaged, it shall be exclusively replaced 
by the manufacturer or his service agent or a similar qualified person in order to avoid a hazard.  
 

 

Please be aware that damages caused by manual modifications to the device are not subject 
to warranty. Keep away from children and non-professionals. 
 

 
3.2) GENERAL GUIDELINES 

 

This device is a lighting effect for professional use on stages, in discotheques, theatres, etc., the 
device was designed for indoor use only. 
 
This fixture is only allowed to be operated with the max alternating current which stated in the 
technical specifications in the last page of this manual.   
 
Lighting effects are not designed for permanent operation. Consistent operation breaks may 
ensure that the device will serve you for a long time without defects. 
 
Do not shake the device.Avoid brute force when installing or operating the device. 
 

Summary of Contents for WALLY-OK7Q

Page 1: ...PROFESSIONAL MOVING HEAD USER MANUAL WALLY OK7Q KEEP THIS MANUAL FOR FUTURE NEEDS...

Page 2: ...mation 13 8 2 1 Time information 13 8 2 2 Temperature Info 14 8 2 3 Software Ver 14 8 3 PERSONALITY 15 8 3 1 Status settings 15 8 3 2 Service setting 17 8 3 3 Fans Control 17 8 3 4 Display setting 18...

Page 3: ...l Please check carefully that there is no damage caused by transportation Should there be any consult your dealer and don t install this device 1 Features 7 x 10W high power LEDs Extremely Long Life 1...

Page 4: ...low the safety instructions and warning notes written in this user manual Important Damages caused by the disregard of this user manual are not subject to warranty The dealer will not accept liability...

Page 5: ...out the plug by tugging the power cord During initial start up some smoke or smell may arise This is a normal process and does not necessarily mean that the device is defective it should decrease grad...

Page 6: ...ort circuit burns electric shock lamp explosion crash etc 4 INSTALLATION INSTRUCTIONS Do not operate this device with open cover 4 1 Mounting the device The applicable temperature for the lighting is...

Page 7: ...screw on the bracket to the 13 hole in the middle of the bracket b Insert the quick lock fasteners of the first Omega holder into the respective holes on the bottom of the device Tighten the quick lo...

Page 8: ...XM894 V1 0 NR 7 Dimensional Drawings...

Page 9: ...f the installation material being used and periodic safety inspection of all installation material and the fixture If you lack these qualifications do not attempt the installation yourself Improper in...

Page 10: ...helps in preventing corruption of the digital control signal by electrical noise The DMX terminator is simply an XLR plug with a 120 resistor connected between pins 2 and 3 which is then plugged into...

Page 11: ...select the desired menu You can change the selection by pressing the the button button button or button Confirm every selection by pressing the button You can leave every mode by pressing the button...

Page 12: ...FF ON OFF Display shutoff time Reverse 180 degree Key Lock No Signal Flash Temperature C F Celsius Fahrenheit Temperature switch between Initial Status PAN XXX Initial effect position Reset Default ON...

Page 13: ...Dmx Value is displayed 3 Press ENTER the display will show Dmx Value 4 Tap the Up Down button choose each channel 5 Press ENTER to confirm or press MODE ESC to return to the main menu 8 1 3 Slave Mod...

Page 14: ...s MODE ESC to return to the main menu Total Run Time With this function you can display the running time of the device The display shows XXXX XXXX stands for the number of hours 1 Tap MODE ESC button...

Page 15: ...u input right password Press ENTER the display will show Clean Last Run 4 The display show OFF Press Up Down the display will show ON 5 Press ENTER to confirm or press MODE ESC to return to the main m...

Page 16: ...ay will show No DMX Mode 4 The display show Hold Press Up Down the display will show Close Shutter Auto Program Music Control 5 Press ENTER to confirm or press MODE ESC to return to the main menu Pan...

Page 17: ...5 Press ENTER to confirm or press MODE ESC to return to the main menu Movement Speed With this function you can select scan mode from 1 to 4 1 Tap MODE ESC button access the main menu Tap the Up Down...

Page 18: ...and makes remote control of devices connected to the DMX bus ANSI E1 20 2006 by ESTA specifies the RDM standard as an extension of the DMX512 protocol Manual settings like adjusting the DMX starting a...

Page 19: ...ed this function 1 Tap MODE ESC button access the main menu Tap the Up Down button until Personality is displayed Press ENTER the display will show Personality Tap the Up Down button until the display...

Page 20: ...R the display will show Personality 2 Press Up Down the display will show Reset Default 3 Press ENTER the display will show Reset Default 4 The display show OFF Press Up Down the display will show ON...

Page 21: ...he Up Down button until Effect Adjust is displayed Press ENTER the display will show Effect Adjust 2 Press Up Down the display will show Calibration 3 Press ENTER the display will show Calibration 4 T...

Page 22: ...e g a Slave unit is set to Slave 1 in the menu Set to Slave the Master unit sends Auto Program Part 1 to the Slave unit If set to Slave 2 the Slave unit receives Auto Program Part 2 To start a Auto P...

Page 23: ...coder to select the desired program With this function you can edit specific scenes into a specific program Press the Enter button to confirm Press the MODE ESC button in order to return to the main m...

Page 24: ...Movement 8bit 0 255 Tilt Movement 17 4 Tilt Fine 16bit 0 255 Fine control of Tilt movement 7 7 5 Speed Pan Tilt movement 0 225 max to min speed 226 235 blackout by movement 236 255 no function 1 1 Re...

Page 25: ...White 8 8 6 Shutter strobe 0 15 Led trun off 16 249 Strobe effect slow to fast 250 255 Led turn on 9 9 7 Dimmer intensity 0 255 Intensity 0 to 100 10 10 8 Color Macro 0 7 No function 8 255 Color Rain...

Page 26: ...ile there are problems with one or more channels XX stands for channel 1 2 3 4 5 6 who has the testing sensor for positioning For example when the display shows Err channel is Pan movement it means th...

Page 27: ...te with unbalances 4 The electric power supply cables must not show any damage material fatigue or sediments Further instructions depending on the installation spot and usage have to be adhered by a s...

Page 28: ...y AC100 240V 50 60Hz Power consumption 130W Packing dimensions 42 5 x 32 x 24 cm Net weight 5 KGS Gross weight 7 5 KGS Remark errors and omissions for every information given in this manual excepted A...

Reviews: