  -                                                                XM155  V1.0  NR           

                 

 

 

If the device has been exposed to temperature changes due to environmental changes, do not switch 
it on immediately. The arising condensation could damage the device. Leave the device switched off 
until it has reached room temperature. 
 
This device falls under protection-class I. Therefore it is essential that the device be earthed. 
The electric connection must carry out by qualified person. 
 
The device shall only be used with rate voltage and frequency.

 

Make sure that the available voltage is not higher than stated at the end of this manual. 
 
Make sure the power cord is never crimped or damaged by sharp edges. If this would be the case, 
replacement of the cable must be done by an authorized dealer. 
 
Always disconnect from the mains, when the device is not in use or before cleaning it. Only handle 
the power cord by the plug. Never pull out the plug by tugging the power cord. 
During initial start-up some smoke or smell may arise. This is a normal process and does not 
necessarily mean that the device is defective, it should decrease gradually. 
 

 

 

Please be aware that damages caused by manual modifications to the device are not subject to 
warranty. Keep away from children and non-professionals. 
 

GENERAL GUIDELINES 

This device is a lighting effect for professional use on stages, in discotheques, theatres, etc. 
This fixture is only allowed to be operated with the max alternating current which stated in the 
technical specifications in the last page of this manual, the device was designed for indoor use only. 
Lighting effects are not designed for permanent operation. Consistent operation breaks may ensure 
that the device will serve you for a long time without defects. Do not shake the device. 
Avoid brute force when installing or operating the device. 
The device shall only be used complete with its protective shield. 
 
While choosing the installation-spot, please make sure that the device is not exposed to extreme heat, 
moisture or dust. The minimum distance between light-output from the projector and the illuminated 
surface must be more than 0.5 meter. 
 

Summary of Contents for V575W

Page 1: ...PROFESSIONAL MOVING HEAD USER S MANUAL V575W KEEP THIS MANUAL FOR FUTURE NEEDS...

Page 2: ...e check carefully that there is no damage caused by transportation Should there be any consult your dealer and don t install this device Features Lamp Philips MSR 575 GOLD SA 2 DE Control channel 16 c...

Page 3: ...structions and warning notes written in this user manual 1 Head 2 Lens 3 Yoke 4 Ventilation fan 5 Control Board 6 Base 7 Carrying handle 8 LCD Display 9 Mode Esc button 10 Up button 11 Down button 12...

Page 4: ...l may arise This is a normal process and does not necessarily mean that the device is defective it should decrease gradually Please be aware that damages caused by manual modifications to the device a...

Page 5: ...this device will be operated in any way different to the one described in this manual the product may suffer damages and the guarantee becomes void Furthermore any other operation may lead to short c...

Page 6: ...shown below Please remember the lamp is not a hot restrike type you must wait for approximately 15 minutes after having turned off the lamp before you can turn it back on again b Mounting the device T...

Page 7: ...ng make sure that the installation area can hold a minimum point load of 10 times the device s weight Connect the fixture to the mains with the power plug Installation method via clamp Please refer to...

Page 8: ...tor This helps in preventing corruption of the digital control signal by electrical noise The DMX terminator is simply an XLR plug with a 120 resistor connected between pins 2 and 3 which is then plug...

Page 9: ...n or Down button Press the Enter button in order to select the desired menu You can change the selection by pressing the Up button or Down button Confirm every selection by pressing the Enter button Y...

Page 10: ...re factory sett Reset Function Reset All Reset Pan Tilt Reset Colors Reset Shutter Reset Others Reset all motors Reset Pan Tilt Reset color wheel Reset shutter and or dimmer Reset other motors Test Ch...

Page 11: ...me Music control With this function you can run the internal program sound controlled Information Time information Power on time With this function you can display the temporary running time of the de...

Page 12: ...ard Select Lamp on off by turning the encoder Press the encoder the display shows ON or OFF Turn the encoder to select ON if you wish to strike the lamp or OFF in order to switch it off Press the enco...

Page 13: ...the DMX value of channel 2 to 7 or 8 When set to 7 you can adjust the starting address between 1 and 255 When set to 8 you can adjust the starting address between 256 and 511 Set the DMX value of chan...

Page 14: ...the Control Board You can select the different reset functions by turning the encoder Effect Adjust Test function of each channel With this function you can test each channel on its correct function L...

Page 15: ...nit sends Auto Program Part 1 to the Slave unit If set to Slave 2 the Slave unit receives Auto Program Part 2 To start a Auto Program please proceed as follows 1 Slave Setting Select Function Mode by...

Page 16: ...tton in order to return to the main menu 5 Automatic Scene Recording Select Edit program by turning the encoder Press the Enter button to confirm Select Edit scenes by turning the encoder Turn the enc...

Page 17: ...from slow to fast Channel 2 Cyan Color Wheel 0 255 Cyan 0 white 255 100 Cyan Channel 3 Magenta Color Wheel 0 255 Magenta 0 white 255 100 magenta Channel 4 Yellow Color Wheel 0 255 Yellow 0 white 255...

Page 18: ...y 0 to 100 Channel 12 Speed Of CMY And Dimmer 0 255 Speed Max Min Channel 13 Color macros CMY and color wheel 0 7 OFF 128 135 Macro16 8 15 Macro1 136 143 Macro17 16 23 Macro2 144 151 Macro18 24 31 Mac...

Page 19: ...vement Er flash repeated for 5 times and then the fixture will generate a reset signal all the stepper reset If the fixture remain error message after performing reset more than 3 times it will detect...

Page 20: ...malfunction sensor failed or magnet missing or the stepping motor is defective or its driving IC on the main PCB The Zoom is not located in the default position after the reset CLEANING AND MAINTENANC...

Page 21: ...0Hz 120VAC 60Hz 208VAC 60Hz 220VAC 60Hz 230VAC 60Hz 240VAC 60Hz Power consumption max 950W Lamp Philips MSR GOLD 575 SA 2 DE Packing dimensions 71X45 5X55cm Net weight 36KGS Gross weight 41 5KGS Remar...