18
- XM155 V1.0 NR
20-39
Color change to any position
40-59
Lamp on
60-79
Lamp switch off
80-84
All motor reset
85-87
Scan motor reset
88-90
Colors motor reset
91-93
No function
94-96
Shutter & Dimmer motor reset
97-99
Other motor reset
100-119 Internal program 1 (scene1~8 of EEPROM)
120-139 Internal program 2 (scene9~16 of EEPROM)
140-159 Internal program 3 (scene17~24 of EEPROM)
160-179 Internal program 4 (scene25~32 of EEPROM)
180-199 Internal program 5 (scene33~40 of EEPROM)
200-219 Internal program 6 (scene41~48 of EEPROM)
220-239 Internal program 7 (scene49~56 of EEPROM)
240-255 Music Control (scene of Program 1)
Channel 15 – Pan fine 16bit
Channel 16– Tilt fine 16bit
ERROR MESSAGE
When you turn on the fixture, it will make a reset first. The display may show “XXer” while there are problems
with one or more channels. “XX” stands for channel 1, 2, 3, 4, 5, 6, 8, 9, 10, 11, 12, 13, 14, 17, 18 who has the
testing sensor for positioning.
For example, when the display shows “Cyan color Er”, it means there is some error in channel 1. If there are some
errors on channel 1, channel 2, channel 5 at the same time, you may see the error message “Color wheel Er”, “Cyan
color Er ”, “Pan movement Er” flash repeated for 5 times, and then the fixture will generate a reset signal, all the
stepper reset. If the fixture remain error message after performing reset more than 3 times, it will detect whether the
fixture has more than 3 errors. If the fixture has more than 3 errors (including 3 errors), all the channels can not
work properly; but if the fixture has less than 3 errors, only the channels which have errors can not work properly,
others can work as usual.
Color wheel Er
(Color wheel- error) This message will appear after the reset of the fixture if the magnetic-indexing circuit
malfunction (sensor failed or magnet missing) or the stepping-motor is defective (or its driving IC on the main
PCB). The color wheel is not located in the default position after the reset.
Cyan Color wheel Er
(Cyan color wheel- error) This message will appear after the reset of the fixture if the magnetic-indexing circuit
malfunction (sensor failed or magnet missing) or the stepping-motor is defective (or its driving IC on the main
PCB). The cyan color wheel is not located in the default position after the reset.
Magenta color wheel Er
(Magenta color wheel- error) This message will appear after the reset of the fixture if the magnetic-indexing circuit
malfunction (sensor failed or magnet missing) or the stepping-motor is defective (or its driving IC on the main