ADVICE TO USERS

The following points will help you
understand how the shower operates:

1

The electric heating elements operate at a

constant rate at your chosen power setting.
It is the flow rate of the water passing
through the heater unit which determines
the shower temperature at any given
setting. (The slower the flow the hotter the
water becomes, and the faster the flow the
cooler the water).

2

During Winter, mains water supply will be

cooler than in Summer. Therefore the
temperature of the shower will vary
between seasons on any one setting of the
temperature control, e.g. if you have chosen
setting number 6 as your preferred shower
temperature in the Summer, you will have to
increase that number during Winter by
adjusting the temperature control clockwise
(which in effect slows the water flow). 

3

The stabiliser valve minimises variations in

shower temperature during mains water
pressure changes. If changes in shower
temperature are experienced during normal
use, it will most likely be caused by the
water pressure falling near to or below the
minimum level. The drop in pressure may be
due to water being drawn off at other
points in the house whilst the shower is in
use. If pressure drops appreciably below the
minimum, the heating elements will
automatically cut out. 

If ever the water becomes too hot and
you cannot obtain cooler water, first
check that the sprayplate in the
sprayhead has not become blocked.

Replacement parts can be ordered from
Customer Service. See 

‘spare parts’

for

details and part numbers.

Due to continuous improvement and updating,
specification may be altered without prior notice.

INTRODUCTION

This book contains all the necessary fitting
and operating instructions for your Triton
T80si electric shower. Please read them
carefully. 

The shower installation must be

carried out by a suitably qualified person
and in the sequence of this instruction book.

Care taken during the installation will ensure
a long, trouble-free life from your shower.

SPECIFICATIONS

Electrical

Nominal power

Nominal power

rating at 240V

rating at 230V

7.5kW – (32A MCB rating)

7.0kW – (32A MCB rating)

8.5kW – (40A MCB rating)

7.9kW – (40A MCB rating)

9.5kW – (40A MCB rating)

8.8kW – (40A MCB rating)

Water

Inlet connection – 15mm diameter.
Outlet connection – 1/2 ”  BSP male thread.

Entry Points

Water – top, bottom, back, left or right.
Cable – top, bottom, back, left or right.

Materials

Backplate, cover, controls, sprayhead – ABS.
Sprayplate – Acetal.
Elements – Minerally insulated corrosion resistant
metal sheathing.

Dimensions

Height - 300mm
Width - 208mm
Depth - 110mm

Standards and Approvals

Triton is registered by the British Standards
Institute to BS EN  ISO 9001:1994.

Complies with the requirements of current British
and European safety standards for household and
similar electrical appliances.

Complies with requirements of the British
Electrotechnical Approvals Board (BEAB).

Meets with Compliance with European
Community Directives (CE).

Summary of Contents for Topaz T80si

Page 1: ...1 2 3 4 5 6 7 8 9 10 INSTALLERS PLEASE NOTE THESE INSTRUCTIONS ARE TO BE LEFT WITH THE USER 2180240D Apr 99 T80si electric sho w er Installation and Operating Instructions ...

Page 2: ...r to the wall 6 Plumbing connections 6 7 Electrical connections 8 Replacing the cover 9 Fitting the riser rail 10 Fitting the hose and sprayhead 11 Commissioning 12 Operating the shower 13 14 Operating functions 14 15 Adjusting the sprayhead 15 User maintenance 16 Fault finding 17 Spare parts 18 19 Volts and amperage reference 20 Guarantee service policy etc rear cover ...

Page 3: ...hen making connections to the flexible hose or sprayhead finger tightness is sufficient 2 6 All plumbing connections MUST be completed BEFORE making the electrical connections 3 ELECTRICAL 3 1 The installation must comply with BS 7671 Requirements for electrical installations IEE wiring regulations or any particular regulations as specified by the local Electrical Supply Company 3 2 This appliance...

Page 4: ...er first check that the sprayplate in the sprayhead has not become blocked Replacement parts can be ordered from Customer Service See spare parts for details and part numbers Due to continuous improvement and updating specification may be altered without prior notice INTRODUCTION This book contains all the necessary fitting and operating instructions for your Triton T80si electric shower Please re...

Page 5: ...rew fixings 3 Cover screw fixings 4 Thermal safety cut out 5 Power selector assembly 6 Can and element assembly 7 Pressure switch flag assembly 8 Stabilising valve 9 Terminal block 10 Earth connection 11 Solenoid valve 12 Water inlet 13 Thermal cut out outlet 14 Pressure relief device PRD 15 Shower outlet Inside cover fig 1a 16 Stop start switch 16 Fig 1a ...

Page 6: ...nit to the shower via a double pole linked switch with a minimum contact gap of 3mm in both poles The switch can be a ceiling mounted pullcord type or a wall mounted switch The switch must be readily accessible and clearly identifiable but out of reach of a person using a fixed bath or shower except for the cord of a cord operated switch The wiring must be connected to that switch without the use ...

Page 7: ...7 shower hose connections requires the sprayhead be constrained by a fixed or sliding attachment so that it can only discharge water at a point not less than 25mm above the spill over level of the relevant bath shower tray or other fixed appliance The use of the supplied soap dish will in most cases meet this requirement but if the sprayhead can be placed within a bath basin or shower tray then a ...

Page 8: ...ctions have been completed PLUMBING CONNECTIONS Plumbing to precede wiring WARNING The outlet of the shower acts as a vent and must not be connected to any tap or fitting not recommended by Triton Plc DO NOT use jointing compounds on any pipe fittings for the installation DO NOT use soldered fittings within the vicinity of the shower unit Compression fittings MUST be used to connect to the inlet o...

Page 9: ... is from the back the nut of the compression fitting will be partially behind the surface of the wall fig 9 This area MUST be left clear when plastering over the pipework in order to make the nut accessible for future adjustments DO NOT use excessive force when making these connections Important Before completing the connection of the water supply to the inlet of the shower and in compliance with ...

Page 10: ...l block screws and ensure that no cable insulation is trapped under the screws NOTE The supply cable earth conductor must be sleeved The outer sheath of the supply cable must be stripped back to the minimum If a cable larger than 10 mm2 is used the cable must be secured either by routing through conduit or in trunking or by embedding in the wall in accordance with current IEE regulations The earth...

Page 11: ...e power selector to the COLD position fig 14 Offer the cover to the backplate unit Attached to the stop start switch inside the cover is a two wire lead The socket on the end of this lead must be connected to the plug that is situated at the bottom of the right hand side of the backplate unit fig 15 NOTE The plug and socket can only fit one way Replace the cover squarely to the backplate and guide...

Page 12: ... Drill and plug the wall C With the saddle spacer and lever parts to hand screw the saddle 2 or 3 turns into the lever fig 18 Place the saddle and lever into the slider holder assembly fig 19 so that the holes align then slide onto the rail fig 20 Tighten to the rail by turning the lever When tight the lever should be facing forwards and not pointing to the wall If not slacken off and remove from ...

Page 13: ...ermost Ensure it locates firmly in the soap dish fig 26 so that it holds the dish at the required height on the rail FITTING THE HOSE AND SPRAYHEAD Feed the flexible hose through the appropriate soap dish aperture fig 27 in order that the dish acts as a retaining ring Water Supply Byelaw 17 Screw the flexible hose to the shower outlet and sprayhead fig 28 ensuring the supplied washers are in place...

Page 14: ...tion fig 31 NOTE Failure to turn the control to 10 may cause the PRD to operate Turn on the mains water supply to the shower at the isolating stop valve and then turn on the electric supply to the shower at the isolating switch The power indicator will light Press the START STOP button fig 32 and wait until water starts to flow from the flexible hose Slowly rotate the temperature control fully ant...

Page 15: ...en the ambient mains water temperature is high during hot months Temperature adjustment at this setting is via the temperature control NOTE If the stated flow rate required for the unit cannot be met due to low water pressure it will be necessary to operate the unit on this setting during the warmer months because of flow rate limitations entering the unit Double red symbol is a high setting which...

Page 16: ...rature is satisfactory by testing with your hand before stepping under the sprayhead There will always be a time delay of 10 to 15 seconds between selecting a flow rate and the water reaching the stable temperature for that flow rate CAUTION It is recommended that persons who may have difficulty understanding or operating the shower controls should not be left unattended whilst showering Special c...

Page 17: ...to flow When the temperature has cooled sufficiently power to the elements will be automatically restored to the previous setting at the time of interruption Safety cut out The unit is fitted with a non re settable over temperature safety device In the event of abnormal operation which could cause unsafe temperatures within the unit the device will disconnect the heating elements It will require a...

Page 18: ... sprayplate sufficiently it can be unscrewed and removed completely fig 39 To remove the cartridge hold firmly and turn anti clockwise until it unscrews from the sprayhead fig 40 Clean the sprayplate and cartridge with a suitable brush or preferably leave them to soak overnight in a mild proprietary descalent Ensure all traces of scale are removed and thoroughly rinse in clean water afterwards Bef...

Page 19: ...e 2 1 1 Increase flow rate via temperature control 2 1 2 Blocked sprayhead clean or replace blocked sprayplate in sprayhead 2 2 1 Check if stop valves are fully open Check if blockage in inlet filter 2 3 1 Re adjust flow rate to give increased flow 2 3 2 Select economy power 3 1 1 See Water too hot causes 2 1 2 2 and 2 3 and their appropriate action cures If it continues contact Triton Customer Se...

Page 20: ...lenoid valve assembly 22007740 Eaton 12 Thermal cut out main 22008310 13 Pressure Relief Device 82800450 14 Stabiliser valve assembly 82600550 15 Start stop switch assembly 83305380 16 Outlet pipe assembly c w wires PRD 85000160 17 Insert trim cover 7052245 18 Insert trim backplate 7052244 Power neon 82300520 Microswitch and wire kit 83305390 12 15 10 11 17 14 16 18 Ref Description Part No ...

Page 21: ...mode sprayhead 22008290 2 Sprayhead holder 83306190 3 Brackets pr 83306160 4 Riser rail 7042409 5 Flexible hose chrome 22007500 6 Soap dish white 22008960 7 Cover assembly c w knobs button 84900010 4 T80si 18 7 3 6 1 2 3 4 5 6 7 8 9 10 ...

Page 22: ... as that shown on the rating label inside the unit If not then these tables will become invalid Important All wiring MUST conform to local regulations If in any doubt always consult a qualified electrician Cable sizes Amperes Cable size mm2 Up to 13 1 5 13 20 2 5 20 26 4 0 26 52 6 0 10 0 Amperage chart UK and export models Unit Rating kW voltage 3 4 5 6 7 7 5 8 8 5 9 5 10 240 12 5 16 6 20 8 25 0 2...

Page 23: ...T80si ...

Page 24: ...e parts 1 By post pre payment of pro forma invoice by cheque or money order 2 By telephone quoting credit card MasterCard or Visa details Triton Plc Shepperton Park Caldwell Road Nuneaton Warwickshire CV11 4NR Triton Plc guarantee this product against all mechanical and electrical defects arising from faulty workmanship or materials for a period of two years for domestic use only from the date of ...