VOLTAGE AND AMPERAGE REFERENCE
The electrical rating of the shower is shown
on the rating label within the unit (see
electrical connections).
The table below can be used to ascertain
amperage given the unit voltage.
NOTE: The elements on UK models are to
240V specification and will give a lower kW
rating if the voltage supply is below 240V.
It is important to ensure that the supply
voltage is the same as that shown on the
rating label inside the unit. If not, then these
tables will become invalid.
Important:
All wiring MUST conform to
local regulations. If in any doubt always
consult a qualified electrician.
Cable sizes
Amperes Cable size (mm
2
)
Up to 13
1.5
13 - 20
2.5
20 - 26
4.0
26 - 52
6.0 - 10.0
Amperage chart
(UK and export models)
Unit
Rating (kW)
voltage
3
4
5
6
7
7.5
8
8.5
9.5
10
240
12.5
16.6
20.8
25.0
29.2
31.2 33.3
35.4
39.6 41.7
230
13.0
17.4
21.7
26.1
30.4
32.6 34.8
36.9
41.3 43.5
220
13.6
18.2
22.7
27.3
31.8
34.0 36.6
38.6
43.0 45.5
210
14.3
19.0
23.8
28.6
33.3
35.7 38.0
40.4
45.2 47.6
T8 0 s i