Triton T40i Installation And Operating Instructions Manual Download Page 14

12

FAULT FINDING/TROUBLESHOOTING

During use, the 
water flow drops to a 
reduced rate. Pump 
stops running.

1.1

  Interrupted power 

supply.

1.1.1

  If the power neon is extinguished, check 

consumer unit fuse or circuit breaker. If blown, 
renew or reset as applicable. If it fails again, 
consult a qualified electrician.

1.1.2

  If the power neon is extinguished, check if a 

general power cut. Check other appliances and 
if necessary, contact local Electricity Supply 
Company.

1.2

  Pump motor faulty.

1.2.1

  If the power neon is lit, have pump motor 

checked by a qualified electrician or contact 
Triton Customer Service.

During use, the water 
flow ceases but the 
pump continues to 
run.

2.1

  Water starvation in 

the system.

2.1.1

  Stop pump motor by switching to ‘stop’. Check 

the cold water cistern is full. Ensure water pipes 
are not blocked. Check there is no simultaneous 
demand from the cistern while showering.

2.2

  Air lock in pump.

2.2.1

  Prime pump by running water through unit 

without electricity switched on.

Water too hot or too 
cold.

3.1

  Not product related 

but problem with 
existing water heating 
system.

3.1.1

  Consult qualified electrician or plumber.

Problem/Symptom

Cause

Action/Cure

FAULT FINDING

Important:

 Switch off the electricity at the mains supply and remove the circuit fuse before  

attempting any fault finding inside the unit.

Problem/Symptom         Cause 

                 Action/Cure

It is advised all electrical maintenance/repairs to the unit should  

be carried out by a suitably qualified person.

In the unlikely event of a fault occurring please contact Triton Customer Service. 

DO NOT remove the shower from the installation.

Summary of Contents for T40i

Page 1: ...recommended for all electrical appliances The hose supplied with this product is an integral part of the safety system Use a genuine Triton handset with this product Failure to use genuine Triton acce...

Page 2: ...al and multiple installations please contact Triton s specification advisory service before installation Telephone E mail 024 7637 2222 technical tritonshowers co uk WARNING This appliance can be used...

Page 3: ...when making connections to the flexible hose or sprayhead finger tightness is sufficient 1 12 All hose connections MUST be completed BEFORE making the electrical connections 2 ELECTRICAL 2 1 The insta...

Page 4: ...r supply NOTE It must NOT be used with instantaneous water heaters This product is suitable for installation in a bathroom DO NOT install the unit so close to the bath that the supplied hose becomes t...

Page 5: ...crew fixings 3 Terminal block 4 Outlet connection 5 Wall screw fixings 6 Rear cable entry 7 Switch assembly 8 Motor 9 Pump assembly 10 Inlet pipe 11 Outlet pipe 12 Inlet connection MAIN COMPONENTS Fig...

Page 6: ...it will NOT be in direct contact with water from the sprayhead Both hot and cold water supplies to the existing bath tap mixer valve MUST be direct and separate from any other outlets or connections D...

Page 7: ...early identifiable but out of reach of a person using a fixed bath or shower except for the cord of a cord operated switch The installation and wiring MUST comply with the current IEE regulations The...

Page 8: ...ig 8 Remove the flexible hose from the T40i and mixer valve Fig 8 Fig 7 Fig 6 WARNING Check there are no hidden cables or pipes before drilling holes for wall plugs Use great care when using power too...

Page 9: ...system and to check for leaks Turn off the water Replace the sprayhead and turn the water on again Leave running to waste until a smooth even if poor flow of water is obtained Turn off the water Fitt...

Page 10: ...r Route the cable into the unit and connect to the terminal block fig 11 as follows Earth cable to terminal marked E Neutral cable to terminal marked N Live cable to terminal marked L IMPORTANT Fully...

Page 11: ...n with the two retaining screws 6 Turn on the water supply at the mixer valve tap and adjust to a normal showering temperature 7 Make sure the control knob is at the stop position Switch on the electr...

Page 12: ...soapy water DO NOT use abrasive or aggressive chemical cleaning products as this may affect the product surface finish and invalidate your guarantee MAINTENANCE Before cleaning turn off the unit at t...

Page 13: ...Ref Description Part No 1 Microswitch 22012460 2 Switch assembly 82500130 3 Outlet pipe assembly 7052027 4 Inlet pipe assembly 7052443 Cover assembly 80400020 Flexible hose chrome 28100240 SPARE PARTS...

Page 14: ...2 1 1 Stop pump motor by switching to stop Check the cold water cistern is full Ensure water pipes are not blocked Check there is no simultaneous demand from the cistern while showering 2 2 Air lock i...

Page 15: ...ic Producers take back scheme PTS registration number WEE EJ3466QV Valpak Distributor take back scheme DTS registration number 9659 All our electric products are labelled accordingly with the crossed...

Page 16: ...credit debit card excluding American Express or Diners Card Payment can also be made by pre payment of a pro forma invoice by cheque or postal order Telephone orders are based on information given dur...

Reviews: