background image

2181599A

 - February 2020

100mm arm available

INSTALLATION AND OPERATING INSTRUCTIONS 

Please read this book thoroughly and familiarise yourself with all instructions before commencing 

installation and keep it for future reference. 
The handwash installation 

MUST

 be carried out by a suitably qualified person, 

in the sequence of 

this instruction book. 

IMPORTANT SAFETY ADVICE

The swivel arm supplied with this product is 

a safety critical part of your shower. Failure to 

use genuine Triton parts may cause injury and 

invalidate your guarantee.

T30I INSTAFLOW

Handwash

FOR YOUR SERVICE REFERENCE

NOTE DOWN THE PRODUCT CODE BELOW

(FROM THE FRONT OR TOP OF THE BOX)

ALTERNATIVELY REGISTER BY TEL: 024 7637 8321

REGISTER ONLINE

ENTER A PRIZE DRAW

WIN

£100

LOVE2SHOP VOUCHERS

VISIT OUR WEBSITE TODAY

TRITONSHOWERS.CO.UK/REGISTER

Summary of Contents for T30i

Page 1: ...n the sequence of this instruction book IMPORTANT SAFETY ADVICE The swivel arm supplied with this product is a safety critical part of your shower Failure to use genuine Triton parts may cause injury...

Page 2: ...ny tap or fitting other than those specified This appliance is intended to be permanently connected to the water mains and not connected by a hose set A suitable double pole isolation switch for suppl...

Page 3: ...thin 300mm of the handwash unit as heat can transfer along the pipework and damage components 2 4 DO NOT fit any form of outlet flow control as the outlet acts as a vent for the heater can 2 5 DO NOT...

Page 4: ...DO NOT place items such as soap or shampoo bottles on top of the unit Liquid could seep through the joint between the cover and back plate and possibly damage the sealing rubber If water becomes too...

Page 5: ...it 8 Fitting the unit to the wall 9 Plumbing connections 10 Electrical connections 11 Fitting the swivel arm and cover 12 Commissioning 13 Operating the handwash 14 Operating functions 14 Cleaning 15...

Page 6: ...lamp bottom 4 Mircoswitch 5 Stabiliser valve 6 Pressure Relief Device PRD 7 Can assembly 3kW 8 Thermal Cut Out TCO 9 Outlet pipe 10 Cover Package Contents Handwash unit Cover screw pack 200mm swivel a...

Page 7: ...g 2 within the unit 2 Before making any sort of electrical connection within the installation make sure that no terminal is live If in any doubt switch off the whole installation at the consumer unit...

Page 8: ...ater inlet mains pipework Fig 3 shows a typical system layout DO NOT use jointing compounds on any pipe fittings for the installation Isolating stopvalve Mains water supply Handwash Diagrammatic view...

Page 9: ...fig 4 Procedure Position the unit on the wall and using the backplate as a template mark the two fixing holes fig 5 Drill and plug the wall An appropriate drill bit should be used If the wall is bric...

Page 10: ...be flushed before the unit is fitted This is to remove any debris within the inlet pipework Procedure Turn off the water supply either at the mains stop valve or the isolating stop valve Make sure the...

Page 11: ...rminal marked Neutral cable to terminal marked N Live cable to terminal marked L IMPORTANT When connecting the cable fully tighten the terminal block screws and make sure that no cable insulation is t...

Page 12: ...ol so that it points at the position fig 12 Replace the cover squarely to the backplate and guide into position so that the control locates correctly into the splined spindle Should any difficulty ari...

Page 13: ...l arm then rotate the control fully clockwise to the maximum flow position fig 15 It will take about thirty seconds for a smooth flow of water to be obtained while air and any debris is being disperse...

Page 14: ...ly permanently connected to the handwash unit when not in use OPERATING FUNCTIONS Low Water Pressure Cut out If the water pressure falls below the minimum required for correct operation of the unit po...

Page 15: ...y should be cleaned at regular intervals to prevent build up of deposits from the water supply Blocked spray holes can reduce the water flow to such an extent that it will cause the thermal cut out or...

Page 16: ...oltage The temperature of the water supply can vary from 5 C in the winter to about 20 C in summer with an average of about 12 C The table below shows a scenario of the water temperature you can expec...

Page 17: ...s If it continues contact Triton Customer Experience 4 1 1 Reduce the flow rate 4 2 1 Is water supply mains or tank fed 4 2 2 If tank fed replumb to mains water supply or see 4 2 4 4 2 3 If mains fed...

Page 18: ...ter pressure has dropped below minimum required 6 1 Blocked sprayhead 5 1 1 Wait until the water pressure resumes to normal 6 1 1 Clean or replace sprayhead and then fit new PRD Note Identify cause of...

Page 19: ...ll our electric products are labelled accordingly with the crossed out wheeled bin symbol This indicates for disposal purposes at end of life that these products must be taken to recognised collection...

Page 20: ...should be made by credit debit card excluding American Express or Diners Card Payment can also be made by pre payment of a pro forma invoice by cheque or postal order Telephone orders are based on in...

Reviews: