Triton T30i Installation And Operating Instructions Manual Download Page 10

10

PLUMBING CONNECTIONS

Plumbing to be carried out before wiring.

DO NOT use jointing compounds on any pipe 
fittings for the installation.
DO NOT use soldered fittings near the unit as 
heat can transfer along the pipework and can 
damage components.
NOTE: An additional isolating valve (complying 
with Water Regulations/Bylaws) MUST be fitted 
in the mains water supply to the unit as an 
independent means of isolating the water supply 
should maintenance or servicing be necessary. If 
this isolator is fitted in a loft space, the loft must 
have a fixed access ladder and be boarded, with 
appropriate lighting from the access point to the 
isolator.

IMPORTANT

: The water inlet pipework to the 

handwash MUST be flushed before the unit is 
fitted. This is to remove any debris within the 
inlet pipework.

Procedure

Turn off the water supply either at the mains 
stop valve or the isolating stop valve.
Make sure the filter is inserted in the pipe before 
connection. This helps to prevent ingress of 
debris (

fig.6

).

Connect the mains water supply to the inlet of 
the unit via 15mm pipe using the nut and olive 
supplied (

fig.7

). 

Check the backplate is square on the wall and 
then tighten the two retaining screws which 
hold it to the wall.
Turn on the mains water supply and check for 
leaks in the pipework connection to the unit.

WARNING!

THE OUTLET OF THE UNIT ACTS AS A

VENT AND MUST NOT BE RESTRICTED. 

ONLY THE SUPPLIED SWIVEL ARM

WITH THE SPRAYHEAD ASSEMBLY OR

 TRIM FITTED SHOULD BE ATTACHED

TO THE UNITS OUTLET. 

DO NOT CONNECT A TAP, HOSE SET, OR 

ANY OTHER FITTING TO THE OUTLET.

Fig.6

Fig.7

Filter

Pipe

Pipe

Nut

Olive

Summary of Contents for T30i

Page 1: ...n the sequence of this instruction book IMPORTANT SAFETY ADVICE The swivel arm supplied with this product is a safety critical part of your shower Failure to use genuine Triton parts may cause injury...

Page 2: ...ny tap or fitting other than those specified This appliance is intended to be permanently connected to the water mains and not connected by a hose set A suitable double pole isolation switch for suppl...

Page 3: ...thin 300mm of the handwash unit as heat can transfer along the pipework and damage components 2 4 DO NOT fit any form of outlet flow control as the outlet acts as a vent for the heater can 2 5 DO NOT...

Page 4: ...DO NOT place items such as soap or shampoo bottles on top of the unit Liquid could seep through the joint between the cover and back plate and possibly damage the sealing rubber If water becomes too...

Page 5: ...it 8 Fitting the unit to the wall 9 Plumbing connections 10 Electrical connections 11 Fitting the swivel arm and cover 12 Commissioning 13 Operating the handwash 14 Operating functions 14 Cleaning 15...

Page 6: ...lamp bottom 4 Mircoswitch 5 Stabiliser valve 6 Pressure Relief Device PRD 7 Can assembly 3kW 8 Thermal Cut Out TCO 9 Outlet pipe 10 Cover Package Contents Handwash unit Cover screw pack 200mm swivel a...

Page 7: ...g 2 within the unit 2 Before making any sort of electrical connection within the installation make sure that no terminal is live If in any doubt switch off the whole installation at the consumer unit...

Page 8: ...ater inlet mains pipework Fig 3 shows a typical system layout DO NOT use jointing compounds on any pipe fittings for the installation Isolating stopvalve Mains water supply Handwash Diagrammatic view...

Page 9: ...fig 4 Procedure Position the unit on the wall and using the backplate as a template mark the two fixing holes fig 5 Drill and plug the wall An appropriate drill bit should be used If the wall is bric...

Page 10: ...be flushed before the unit is fitted This is to remove any debris within the inlet pipework Procedure Turn off the water supply either at the mains stop valve or the isolating stop valve Make sure the...

Page 11: ...rminal marked Neutral cable to terminal marked N Live cable to terminal marked L IMPORTANT When connecting the cable fully tighten the terminal block screws and make sure that no cable insulation is t...

Page 12: ...ol so that it points at the position fig 12 Replace the cover squarely to the backplate and guide into position so that the control locates correctly into the splined spindle Should any difficulty ari...

Page 13: ...l arm then rotate the control fully clockwise to the maximum flow position fig 15 It will take about thirty seconds for a smooth flow of water to be obtained while air and any debris is being disperse...

Page 14: ...ly permanently connected to the handwash unit when not in use OPERATING FUNCTIONS Low Water Pressure Cut out If the water pressure falls below the minimum required for correct operation of the unit po...

Page 15: ...y should be cleaned at regular intervals to prevent build up of deposits from the water supply Blocked spray holes can reduce the water flow to such an extent that it will cause the thermal cut out or...

Page 16: ...oltage The temperature of the water supply can vary from 5 C in the winter to about 20 C in summer with an average of about 12 C The table below shows a scenario of the water temperature you can expec...

Page 17: ...s If it continues contact Triton Customer Experience 4 1 1 Reduce the flow rate 4 2 1 Is water supply mains or tank fed 4 2 2 If tank fed replumb to mains water supply or see 4 2 4 4 2 3 If mains fed...

Page 18: ...ter pressure has dropped below minimum required 6 1 Blocked sprayhead 5 1 1 Wait until the water pressure resumes to normal 6 1 1 Clean or replace sprayhead and then fit new PRD Note Identify cause of...

Page 19: ...ll our electric products are labelled accordingly with the crossed out wheeled bin symbol This indicates for disposal purposes at end of life that these products must be taken to recognised collection...

Page 20: ...should be made by credit debit card excluding American Express or Diners Card Payment can also be made by pre payment of a pro forma invoice by cheque or postal order Telephone orders are based on in...