10
Electric shower
Isolating
stopvalve
Mains
water
supply
Shower
unit
Mains electric supply
(via double pole switch)
Double
pole
isolating
switch
Separate permanently
connected supply
from consumer unit
SITING OF THE SHOWER
The installation must be in accordance with
Water Regulations/Bylaws -
see page 7 for
water specifications
If it is intended to operate the shower at
pressures above the maximum or below the
minimum stated, contact Customer Experience
for advice.
If the stated flow rates are not available,
it may not be possible to achieve optimum
performance from the unit throughout
the year.
During periods of high ambient temperatures
it may be necessary to select the economy
power setting to achieve your preferred shower
temperature.
Fig.5
shows a typical system layout.
NOTE:
The control knobs are an integral part
of the cover.
Do not attempt to remove
them.
• Lift the cover from the backplate.
• Refer to
(fig.6)
for the correct siting of
the shower. Position the unit where it will
NOT
be in direct contact with water from
the shower head. Position the shower unit
vertically.
• Allow enough room between the ceiling and
the shower to access the cover top screws.
• Mark out entry points and routing of the
water and electric supplies into the shower.
Fig.5
Wiring can be positioned left
or right side of shower for
installation.
Plumbing can be fitted
from the left or right.