17
9
Step
Step
DRAIN PUMP CONNECTIVITY
INSTALLATION
(If no drain pump is being connected to the shower then this step can be ignored)
The Omnicare has been designed to operate with the most popular drain pumps
found on the market, please take the time to fully understand the type of drain pump
being fitted and the connection required to the shower.
Configuration 1 for Analogue Drain Pumps
When the shower is turned on, a signal is sent to the drain pump electronics telling
the pump to start. When the shower is turned off, a signal is sent again to the drain
pump electronics telling the pump to stop; generally after a preset time delay. This
type of pump makes no allowance for the flow rate of the water from the shower, the
‘gulp’ or speed of the pump is fixed.
ON
1
2
3
4
5
DIP switch 4
On
Analogue Pump Setting
The pump manufacture provides a two core cable for connection to the shower
unit.
Connect the drain pump control wire as below:
1 - Not Used (connections are numbered)
2 - Any
3 - Any
Note: Please reference the relevant pump manufacturers installation
instructions for pump connection and relevant IEE regulations.
Control wire to connect
the shower to the pump
transformer module.
Pump
wire
terminal
block
1
2
3