Bezique
9
Power on
indicator
Low pressure
indicator
Selector
mode
indicators
OPEraTiNG fuNCTiONS
Power on indicator
(fig.34)
When the electricity supply to the shower is
switched on at the isolating switch, the POWER
indicator will light.
low pressure indicator
(fig.34)
If this indicator lights, this means the water
pressure has fallen below the minimum required
for correct operation of the shower, resulting in
the low pressure cut-out operating. This switches
off power to the heating elements preventing any
undue temperature rises (water will continue to
flow). Power will automatically be restored when
adequate water pressure returns.
Selector mode indicators
(fig.34)
next to each control button there is an indicator
that lights when the button is pressed, indicating
which shower mode is in operation.
Phased shutdown
In use, when the stop button is pressed, power is
switched off to the elements. Water will continue
to flow for a few seconds, flushing out any
remaining hot water. This makes sure the next
immediate user will not receive a slug of hot
water if standing under the showerhead when
starting the shower.
Temperature limiter
During normal operation if an overheat
temperature is sensed, power to the elements
will be reduced. Water will continue to flow.
When the temperature has cooled sufficiently
power to the elements will be automatically
restored to the setting at the time of
interruption.
Safety cut-out
The unit is fitted with a non-resettable
thermal cut-out safety device. In the event of
abnormal operation which could cause unsafe
temperatures within the unit, the device will
disconnect the heating elements. It will require a
visit from a qualified engineer to determine the
nature of the fault and replace the safety device,
once the unit has been repaired.
Fig.