background image

Bezique

ElECTriCal rEquirEmENTS

The installation, supply cable and circuit 
protection must conform with bS7671 (IEE 
wiring regulations) and be sufficient for the 
amperage required.
The following notes are for guidance only:

1

 

The shower must only be connected to a 
230-240V ac supply. If you are installing a 
shower with a kilowatt rating above 9kW, it 
is advisable to contact the local electricity 
supply company.

1.1

  The electrical rating of the shower is shown 

on the rating label 

(fig.)

 within the unit.

2

 

before making any sort of electrical 
connection within the installation make 
sure that no terminal is live. If in any doubt, 
switch off the whole installation at the 
consumer unit.

3

 

The shower must be connected to its own 
independent electrical circuit. IT MUST 
nOT be connected to a ring main, spur, 
socket outlet, lighting circuit or cooker 
circuit.

3.1

  The electrical supply must be adequate for 

the loading of the unit and existing circuits.

4

 

Check your consumer unit (main fuse box) 
has a main switch rating of 80A or above 
and that it has a spare fuse way which will 
take the fuse or MCb necessary for the 
shower 

(fig.)

.

4.1

  If your consumer unit has a rating below 

80A or if there is no spare fuse way, then 
the installation will not be straightforward 
and may require a new consumer unit 
serving the house or just the shower.

4.2

  You will need to contact the local electricity 

company. They will check the circuit and 
carry out what is necessary. They will also 
check the main bonding.

5

 

The earth continuity conductor of the 
electrical installation must be effectively 
connected electrically to all exposed metal 

Meter 

Incoming 

supply 

fuse 

Meter 

tails 

Consumer 

unit 

Pull cord 

isolating switch 

Shower 

unit 

Fuse or 

MCB 

RCD 

(can be part of 

consumer unit) 

80A or 100A 

main switch 

Fig.  

Schematic of installation circuit

Shepperton Park,

Triton Road, Nuneaton,

Warwickshire, CV11 4NR

Fig.

WARNING!

thIs ApplIANce must be eARthed

table A

cIRcuIt pRotectIoN

  unit 

 

cartridge 

  rating 

mcb 

fuse

  7.0kW 

30/32A 

30A

  7.5kW 

32A 

35A

  8.0kW 

40A 

35A

  8.5kW 

40A 

45A

  9.0kW 

40A 

45A

  9.5kW 

40/45A 

45A

  10.5kW 

45A 

45A

Summary of Contents for Bezique

Page 1: ...low pressure power Installers please note these instructions are to be left with the user 2180225L March 2006 Installation and operating instructions Bezique electric shower...

Page 2: ...cover 14 Fitting the riser rail 15 16 Fitting the hose and sprayehead 16 Operating the shower 17 18 Operating functions 19 Adjusting the showerhead 20 Cleaning the showerhead 21 Cleaning the inlet fil...

Page 3: ...is sufficient 2 6 All plumbing connections must be completed before making the electrical connections 3 Electrical 3 1 The installation must comply with BS 7671 Requirements for electrical installatio...

Page 4: ...water becomes and the faster the flow the cooler the water b During winter the mains water supply will be cooler than in the summer so the flow rate will vary between seasons at any one temperature s...

Page 5: ...assembly 12 Thermal cut out main 13 Earth connection 14 Outlet temperature limiter 15 Trimplate Inside cover fig 2 16 Cover tags 17 Control PCB Pack contents Shower unit Five position showerhead Riser...

Page 6: ...4 Check your consumer unit main fuse box has a main switch rating of 80A or above and that it has a spare fuse way which will take the fuse or mcb necessary for the shower fig 4 4 1 If your consumer...

Page 7: ...those rooms must be protected by a 30mA RCD 9 The current carrying capacity of the cable must be at least that of the shower circuit protection see table B 9 1 To obtain full advantage of the power p...

Page 8: ...al Water Authority or consult a competent plumber During periods of high ambient temperatures it may be necessary to select a low power setting to achieve your preferred shower temperature The water s...

Page 9: ...fitted in the supply pipework to prevent back flow Pressure relief safety device A pressure relief device PRD is designed into the shower unit which complies with European standards The PRD provides a...

Page 10: ...ed to be cut out in the trimplate and cover fig 9 If surface cable entry from the top is required then a small area will need to be cut out in the backplate fig 10 If installing a feed pipe from the r...

Page 11: ...t building block you must use suitable wall plugs and an appropriate drill bit Screw top fixing screw into position leaving the base of the screw head protruding 6mm out from the wall Hook the backpla...

Page 12: ...the shower flush out the pipework to remove all swarf and system debris This can be achieved by connecting a hose to the pipework and turning on the mains water supply long enough to clear the debris...

Page 13: ...conductor must be sleeved The outer sheath of the supply cable must be stripped back to the minimum The supply cable must be secured either by routing through conduit or in trunking or by embedding i...

Page 14: ...the 10 way ribbon cable at this stage Carefully locate the cover tags into the guide pockets on the backplate and make sure the wires are not trapped Guide the cover into position so that the control...

Page 15: ...flow and back again several times to release any trapped air from within the unit Once the flushing out has been completed switch off the electricity to the shower at the isolating switch The water w...

Page 16: ...te and make sure the wires are not trapped Guide the cover into position so that the knob spindle locates correctly minor adjustment may be necessary to align the knob and spindle Should any difficult...

Page 17: ...cut out on the bracket end fig 23 Locate the second bracket on top of the rail Check the rail is vertical then mark the centre hole and of the other two holes Remove the bracket and rail Drill and pl...

Page 18: ...so it holds the dish at the required height on the rail Fitting the hose and Showerhead Feed the flexible hose through the appropriate soap dish opening fig 30 so that the dish acts as a retaining rin...

Page 19: ...re control The centre button blue symbol is for cold water only Adjusting the temperature control at this setting will only increase or decrease the force of the water from the showerhead It will not...

Page 20: ...numbers To increase the shower temperature Turn the temperature control clockwise this will decrease the flow of water through the shower and is indicated by higher numbers Note It is advisable to be...

Page 21: ...operation Phased shutdown In use when the stop button is pressed power is switched off to the elements Water will continue to flow for a few seconds flushing out any remaining hot water This makes sur...

Page 22: ...our shower is supplied with a five position showerhead with a rub clean face Five showerhead patterns are available fig 35 Adjust the spray pattern by turning the bezel on the showerhead in either dir...

Page 23: ...anti clockwise fig 37 This movement may turn the cartridge assembly as well until it reaches a stop Hold the cartridge firmly and continue to twist anti clockwise Having loosened the sprayplate it ca...

Page 24: ...pipe which is part of the solenoid valve fig 38 To gain access to the filter remove the trimplate then disconnect and remove the compression fitting Also depending on the incoming pipework arrangemen...

Page 25: ...10 5kW 84500670 4 Stabiliser valve assembly 9 5kW 82600870 10 5kW 82200850 5 Solenoid valve assembly 83304130 6 Thermal cut out 22009860 7 PRD O ring 83301330 8 Outlet pipe assembly 85000130 9 Trimpla...

Page 26: ...Ref Description Part No 11 5 mode showerhead 22010980 12 Wall bracket 83306160 13 Showerhead holder 83306190 14 Riser rail 7042409 15 Soap dish 22008960 16 Flexible hose 28100080 SPARE PARTS 11 12 13...

Page 27: ...ps are fully open Check if blockage in inlet filter 2 3 1 Switch to economy power setting and readjust flow rate to give required temperature 3 1 1 See Water too hot causes 2 1 2 2 and 2 3 and their a...

Page 28: ...s to normal Low pressure indicator extinguishes 6 1 1 Clean sprayplate and then fit a new PRD 6 2 1 Check for free passage through hose Replace hose if necessary and then fit new PRD 6 3 1 Fit new PRD...

Page 29: ...Bezique 27...

Page 30: ...Bezique 28...

Page 31: ...Bezique 29...

Page 32: ...order 2 By telephone quoting credit card MasterCard or Visa details 3 By website order www tritonshowers co uk Triton Standard Guarantee Triton Plc guarantee this product against all mechanical and e...

Reviews: