background image

Triton Systems ©

15

TDN 07103-04303

36. Load notes not in cassette. Insert cassette into dispenser, then press the 

Enter 

button. 

37. The dispenser cycles a note into the Reject cassette.

38. Denomination is the type of note loaded ($5, $10, $20 etc.). Use the on-screen numeric keypad to enter the 

denomination of notes loaded. Press the 

Enter and Return

 button to save the value. The screen will return to 

the 

Cassette Parameter

 menu. 

 

39. Press the 

Save and Return

 button to return to the 

Cassette Dispenser Diagnostics

 

menu.

40. Press the 

Exit Management Functions

 button and return ATM for customer use.  

End of MMR050 Procedure

Summary of Contents for atmgurus ARGO SDD TO MMR50

Page 1: ...Delaware LLC The third party trademarks that may be identified herein are the trademark of their respective owners Triton disclaims any affiliation connection or association between its products and...

Page 2: ...opt 3 for Technical Support 228 575 3101 fax CSS triton com techsupport triton com purpose This guide covers configuration information for Level 1 Vault and Business Hours deep cabinet ATMs scope Thi...

Page 3: ...ut driver 11 32 socket Kit P N 06200 02085 ARGO SDD to MMR50 Conversion Kit Parts Supplied Description Quantity 1 NMDComms Cable 1 2 Mech Tray ground Wire 58 1 3 Security Module and MiniMech MMR50 Pow...

Page 4: ...follow instructions to load the correct software for your ARGO ATM If the ATM has the minimum required software perform a proper shut down of the unit and disconnect the input power cord from the powe...

Page 5: ...e out enough to reach the power and communications cable in the back 4 On the back of the dispenser loosen the two thumbscrews and remove the communication cable Left Image Disconnect the power cable...

Page 6: ...e Security Module to main board communication cable in the clips Left Image shows the four cable clips Right Image shows a close up for clips 1 and 2 8 Left Image disconnect the SDD to Security Module...

Page 7: ...cket nuts and screw for later use 10 Using the 11 32 hollow nut drive disconnect the ground wire RED Arrow Save the Keps nut for later use Disconnect the SDD power plug and Security Module power plug...

Page 8: ...nut from step 10 to secure the ground wire to the power supply 13 Route the dispenser and Security Module power cable through the four clips shown Left Image Plug the two prong plug into the security...

Page 9: ...power cable TY Wrap the power and data cables together Trim excess TY Wrap 16 Pull the excess Data cable back up to the clips and make a Bow Left Image Place the excess cable into the clip Right Image...

Page 10: ...ap the tubing at the opposite end Trim excess TY Wrap Right Image 19 From the kit obtain clip Item 6 and slip over the tube Secure clip to rail using screw Item 4 20 Route the ground wire through the...

Page 11: ...he three nuts with a 11 32 hollow nut driver Note May need to disconnect the input power cord to the power supply and remove the power supply by loosening the two nuts under the power supply then lift...

Page 12: ...cable into the dispenser Left Image Route the data cable behind the power cable and plug into the dispenser Right Image 26 Bend the clip around the Data cable to keep it in place Left Image Bend the...

Page 13: ...ot bind or interfere with any moving parts If no cable binding push the tray until the rail latches the tray in Right Image 29 Open the control panel and plug the input power cord into the power suppl...

Page 14: ...tinue Initialization will take several minutes Should hear the dispenser cycle before seeing the Dispenser Initialization complete screen Press the Enter button to continue 33 Navigate to Management F...

Page 15: ...ype of note loaded 5 10 20 etc Use the on screen numeric keypad to enter the denomination of notes loaded Press the Enter and Return button to save the value The screen will return to the Cassette Par...

Page 16: ...Triton Systems 16 TDN 07103 04303...

Reviews: