21. Use the screw from
step 6
to attach the ground wire to the tray,
Left Image
. Place the tubing over the door,
Right Image
.
22. Install the cable cover removed earlier. Use extreme caution
NOT
to pinch any of the cables. Secure cover
with screw removed earlier. Inside of the vault, secure the three nuts with a 11/32” hollow nut driver.
**Note**
May need to disconnect the input power cord to the power supply and remove the power supply by loosening
the two nuts under the power supply, then lift up the power supply and set on cabinet floor. After securing the
cable cover, install the power supply to cabinet wall.
23. Obtain the MMR050 dispenser and remove the cassette. Using the T20 Torx screwdriver, remove the two
screw,
RED
arrows,
GREEN circles
, and install two cable clamps,
Item 7
, with same screws to the chassis.