The following can be carried out by a competent person

FAULT FINDING

1

 

Water too hot. 
 

 

 

 

 
 

 

 
 

2

 

Water too cold. 
 

 

 

 

 
 
 

 

High water flow 
and/or poor 
performance on a 
mains fed system.

1.1

 Temperature 

control incorrectly 
commissioned.

1.2

  Not enough cold 

water flowing through 
shower.

1.3

  Increase in the 

ambient cold water 
temperature.

1.4

  Cold water supply 

blocked. 

1.5

  High volume of cold 

water drawn off 
elsewhere.

2.1

  Temperature control 

incorrectly 
commissioned.

2.2

 

Not enough hot water 
flowing through 
shower.

2.3

  Decrease in the 

ambient cold water 
temperature.

2.4

  Insufficient hot water 

supplies from the 
heating system. 

2.5

  Hot water supply 

blocked or restricted. 

2.6

  Flow regulator not 

fitted (HP systems 
only).

3.1

  Flow regulators not 

fitted.

1.1.1

 Refer to the Commissioning section. 

 

1.2.1

 Reposition temperature control knob 

 

1.3.1

 Reposition temperature control knob. 

 

1.4.1

 Turn off the shower and consult a 

competent plumber or contact  
Customer Experience.

1.5.1

 

Reduce the simultaneous demand from  
the supply. 

2.1.1

 Refer to the Commissioning section. 

 

2.2.1

 Reposition temperature control knob

 

2.3.1

 Reposition temperature control knob

2.4.1

 Make sure heating appliance is set to 

maximum or has sufficient stored hot water.

2.4.2

 

Make sure heating appliance is igniting by 
trying a hot water tap elsewhere.

2.5.1

 Turn off shower and consult a competent 

plumber or contact Customer Experience. 

2.6.1

 

Fit the supplied flow regulator 

(Page 11)

.

3.1.1

 

Fit the supplieed flow regulator 

(Page 11)

.

Problem Cause 

Action

Summary of Contents for ASTI LEVER

Page 1: ...ISTER BY TEL 024 7637 8321 INSTALLATION AND OPERATING INSTRUCTIONS Please read this book thoroughly and familiarise yourself with all instructions before commencing installation and keep it for future...

Page 2: ...11 FLOW REGULATION 11 TEMPERATURE ADJUSTMENT RANGE 12 ADJUSTING THE MAXIMUM TEMPERATURE SETTING 12 OPERATING THE SHOWER 13 DIMENSIONS 14 APPROVALS 15 PRODUCT FLOW RATES 15 MAINTENANCE 16 FAULT FINDIN...

Page 3: ...s fitting book regarding the product and installation are approximate All kits are for illustration purposes only and are not supplied unless otherwise stated MAIN COMPONENTS Fig 1 A Thermostatic bar...

Page 4: ...mixer shower Water Minimum Flow Rate For best performance within the specified running pressure range a minimum flow of 8 litres per minute should be available to both inlets Water Temperature Requir...

Page 5: ...is not flushed through before fitting Commercial Applications It is recommended that for all commercial applications easily accessible in line filters are used to aid maintenance Hard Water Areas a If...

Page 6: ...t pressures as shown please refer to the pump installation guide to establish the minimum head requirements for automatic operation of the pump Hot water cylinder Cold supply Hot supply Alternative su...

Page 7: ...systems with no cold water take off after the appliance reducing valve it will be necessary to fit an additional drop tight pressure reducing valve when the mains pressure is over 5 bar The drop tigh...

Page 8: ...running An expansion vessel MUST be fitted and regularly maintained to ensure the unit is not damaged by excess pressures This may already be installed externally or internally within the thermal sto...

Page 9: ...work to the shower area having decided on the position of the shower and direction of pipe entry for example rising falling or rear entry The hot and cold water pipes should be securely attached withi...

Page 10: ...bow fittings in solid wall installations The inlet centres on the variable connectors have a degree of adjustment to allow for misalignment of pipe work The hot and cold supply pipes MUST be anchored...

Page 11: ...ess fig 9 Screw the supplied cover trims onto the fittings until tight to the wall fig 10 FITTING THE SHOWER IMPORTANT Make sure that all supply pipework has been flushed through before fitting the mi...

Page 12: ...nder of the graphic should run towards you If fitted correctly the graphic and flow control should now be sitting in the designed OFF position Once in place fit the retaining screw Do not fit the end...

Page 13: ...m temperature override button Allow the shower to run at this maximum temperature setting until the water temperature has stabilised Rotate the temperature control until your desired maximum showering...

Page 14: ...mperatures must never exceed 46 C at terminal fitting The British Burns Association recommends 37 to 37 5 C as a comfortable bathing temperature for children In premises covered by the Care Standards...

Page 15: ...s flowing fig 16 To adjust the water temperature rotate the temperature control right hand side clockwise for a cooler shower or anti clockwise for a hotter shower fig 17 To overcome the maximum tempe...

Page 16: ...Inclusive Bar Mixer Shower 14 290 00 1 2 BSP 180 00 150 00 3 4 BSP 4 0 5 0 56 25 DIMENSIONS All dimensions regarding the product and installation are approximate...

Page 17: ...ure shower only PRODUCT FLOW RATES Flow Rate l m 5 0 6 9 9 0 10 9 12 0 17 5 25 5 31 5 36 5 41 0 Pressure bar 0 1 0 2 0 3 0 4 0 5 1 0 2 0 3 0 4 0 5 0 Conditions for test Inlet temperatures comply with...

Page 18: ...itially check the filters for debris once every three months and clean if necessary b Perform a thermal shut off test every three months and check the maximum temperature setting See the Commissioning...

Page 19: ...ocked or restricted 2 6 Flow regulator not fitted HP systems only 3 1 Flow regulators not fitted 1 1 1 Refer to the Commissioning section 1 2 1 Reposition temperature control knob 1 3 1 Reposition tem...

Page 20: ...the inlet filters Clean if necessary 4 3 1 Turn off the shower and consult a suitably competent plumber 4 4 1 Clean shower head 4 5 1 Reduce the simultaneous demand 4 5 2 Make sure stop service valves...

Page 21: ...Inclusive Bar Mixer Shower 19...

Page 22: ...Inclusive Bar Mixer Shower 20...

Page 23: ...Inclusive Bar Mixer Shower 21...

Page 24: ...ent of a pro forma invoice by cheque or postal order Telephone orders are based on information given during the call Before contacting Triton please verify your requirements using the Information cont...

Reviews: