background image

 

 

PROFESSIONAL MOVING HEAD USER’S MANUAL

 

 

 

 

V700S-E 

 

 

 
 

KEEP THIS MANUAL FOR FUTURE NEEDS

 

 

 

Summary of Contents for V700S-E

Page 1: ...PROFESSIONAL MOVING HEAD USER S MANUAL V700S E KEEP THIS MANUAL FOR FUTURE NEEDS...

Page 2: ...Pan tilt movement 8 bit and 16 bit resolution For smooth and precise resolution Pan 540 630 optional Tilt 265 movement High speed of pan tilt movement speed of pan tilt movement is adjustable Scan po...

Page 3: ...ernal controller up to 250 scenes can be saved and then can be run in Stand Alone or sound activated Number of scenes in Program Run can be changed individually OVERVIEW 1 Projector head 2 Objective l...

Page 4: ...cord is never crimped or damaged by sharp edges If this would be the case replacement of the cable must be done by an authorized dealer Always disconnect from the mains when the device is not in use...

Page 5: ...he device Most damages are the result of unprofessional operation Please use the original packaging if the device is to be transported For safety reasons please be aware that all modifications on the...

Page 6: ...lamp to get the maximum light output as shown below Please remember the lamp is not a hot restrike type you must wait for approximately 15 minutes after having turned off the lamp before you can turn...

Page 7: ...ng load limits installation material being used and periodic safety inspection of all installation material and the device If you lack these qualifications do not attempt the installation yourself Imp...

Page 8: ...and the other side to the male 3 pin XLR input of the moving head You can chain multiple Moving head together through serial linking The cable needed should be two core screened cable with XLR input...

Page 9: ...ther words changing the settings of one channel will affect all the fixtures simultaneously If you set a different address each unit will start to listen to the channel number you have set based on th...

Page 10: ...mp Off No DMX Lamp On at Temp Lamp Off at Temp ON OFF ON OFF ON OFF ON OFF OFF 0FF 19M 20 79 45 68 174 113 80 139 130 176 282 266 Lamp on off Lamp on off when Power on Lamp on via DMX Lamp off via DMX...

Page 11: ...Program in loop Save and exit Edit Scenes Edit Scene 001 Edit Scene 250 Pan Tilt Secne Time Input By Outside Pan xxx TIME xx xs Save and automatically return manual scenes edit Edit Program Rec Contro...

Page 12: ...n menu Temp Info Base Temp With this function you can display the temperature in the projector base near LCD display in Celsius Head Temp With this function you can display the temperature on the disp...

Page 13: ...by turning the encoder if you wish to switch off the lamp automatically at once Select 19M by turning the encoder if you wish to postpone to 19 minutes switch off the lamp automatically Lamp on at te...

Page 14: ...slow or quick Feedback With this function you can feedback switch of pan movement or tilt movement Movement Speed With this function you can select scan mode from 1 to 4 Mic Sensitivity With this fun...

Page 15: ...equence For example after the user enter this manual if select Auto Program CH 22 means in this User s mode the Dimmer is in Channel 16 User mode With this function you can create user defined channel...

Page 16: ...rn to the main menu 3 Program selection for Auto Pro Part Select Edit program by turning the encoder Press the Enter button to confirm Select Select programs by turning the encoder Press the Enter but...

Page 17: ...Part 3 is Program 6 The 3 Slave groups run the Auto Program in certain time segments as shown in the following picture INSTRUCTIONS ON USE DMX channel s functions and their values 24 DMX channels Cha...

Page 18: ...cont rotation 0 9 Open 10 19 Rot gobo 1 20 29 Rot gobo 2 30 39 Rot gobo 3 40 49 Rot gobo 4 50 59 Rot gobo 5 60 69 Rot gobo 6 70 89 Gobo 1 shake slow to fast 90 109 Gobo 2 shake slow to fast 110 129 Go...

Page 19: ...tating gobo index rotating gobo rotation 0 127 Gobo indexing 128 189 Forwards gobo rotation from fast to slow 190 193 No rotation 194 255 Backwards gobo rotation from slow to fast Channel 12 3 facet r...

Page 20: ...r open 192 223 Random strobe effect slow to fast 224 255 No function shutter open Channel 16 Dimmer intensity 0 255 Intensity 0 to 100 Channel 17 Iris 0 191 Max diameter to Min diameter 192 223 Pulse...

Page 21: ...annel 22 Lamp on off reset internal programs 0 19 color gobo change normal 20 29 color change to any position 30 39 color gobo change to any position 40 59 Lamp on 60 79 Lamp switch off 80 84 All moto...

Page 22: ...his message will appear after the reset of the fixture if the magnetic indexing circuit malfunction sensor failed or magnet missing or the stepping motor is defective or its driving IC on the main PCB...

Page 23: ...tor is defective or its driving IC on the main PCB The Iris is not located in the default position after the reset Zoom Er Zoom error This message will appear after the reset of the fixture if the mag...

Page 24: ...rom your local dealer TECHNICAL SPECIFICATIONS Power supply 100VAC 50Hz 120VAC 50Hz 208VAC 50Hz 220VAC 50Hz 230VAC 50Hz 240VAC 50Hz 100VAC 60Hz 120VAC 60Hz 208VAC 60Hz 220VAC 60Hz 230VAC 60Hz 240VAC 6...