23
TRI153.INS.046.3 - 08 March 2021
RTM - 75kW User Unit Installation Manual
www.tritium.com.au
Veefil®isaregisteredtrademarkofTritiumPtyLtd.©2021TritiumPtyLtd
Wiring in - Alternative gland plate
3. Install alternative gland plate
Use the 6x M5 nuts and install the
alternative gland plate under the
RTM-75kW chassis. Torque to 6Nm.
CRITICAL
To continue to achieve the IP65 rating
the power cabling must be fitted
correctly into the cable gland.
Ensure the cable is sitting correctly in
the gland and tighten to ensure no water
or debris can enter. If in doubt, use an
appropriate outdoor rated sealant.
When the cable gland has been
tightened, pull on the cable to ensure it
doesn’t slip.
The alternative gland plate is required
when individual HP input wiring is used.
Prepare all wiring as per underground or
above ground gland installation.
Note that each scenario has different
wiring trim lengths.
1. Remove existing gland plate
The gland plate is fixed under the
RTM-75kW chassis. Unscrew the 6x M5
nuts and remove the existing gland plate.
Keep the nuts.
2. Prepare alternative gland plate
Assemble the 4x M32 and 1x M25 onto
the alternative gland plate with the nuts
on the gasket side. Torque to 2Nm.