![Tritech Seanet Series Manual Supplement Download Page 9](http://html1.mh-extra.com/html/tritech/seanet-series/seanet-series_manual-supplement_1168956009.webp)
Tritech International Ltd
Seanet System- Sonar Aux MDL Gyro
Issue 2
TIL – Eng – Spec – 064
Page 10 of 15
d)
From here press the Baud Rates Button...
…Check Baud rates on
Async 1 (AUX)
match the device output (default Digiquartz output
is 9600 baud).
2.
Now change the jumper settings on the Comms board inside the Head. In the SeaKing head,
this must be a COMDV3/FV3, COMGV3/V5 or a COMV5 Mod-A board.
The jumpers should be set as follows - refer to the option that suits your configuration.
<< See the 4 options that now follow >>
Caution
!
Ensure that the sonar Aux port is fitted with a Water Block
connector
.