Seanet SCU v5
0581-SOM-00002-02
Tritech International Ltd.
Page 16 of 35
6. System Software Configuration
Your system will be delivered with Windows Embedded and Seanet System Software
pre-installed.
A complete image of the Windows Embedded Operating System is provided on an
internal flash memory device. This is independent from the Primary C:\ partition
where the system software is installed to. This image can be re-installed at any time
through a Boot Recovery process to restore the Primary C:\ partition to a factory
default state.
The Boot Recovery process is initiated via a switch on the rear panel of the SCU.
Files on the C:\ partition are re-installed during the recovery process, leaving user
files on the D: drive unaffected.
There are 2 levels of restoration that can be carried out:
1. Re-installation of the Seanet Pro software only to factory default. It is
recommended where possible that this is attempted before level 2 in order to
recover the SCU.
2. Complete Re-installation of the Primary C:\ partition to factory supplied condition.
Use of this level will erase all files currently stored on the C:\ drive and replace
with a factory installation state. D:\ drive user files will be unaffected. The D:
\ drive is also where a copy of the Seanet Pro software installer and Operator
manuals can be located.
6.1. Seanet System Re-Installation
The SEANET SCU has the following Drive Letters:
Drive C:\
Primary, Flash Memory boot drive where system files and Seanet
software are installed. This drive should NOT be used for storing any
log files.
Drive D:\
This drive is where the Seanet software installer and operator
manuals can be found. There is space to use this drive for user files
and log files. The ‘My Documents’ folder has also been moved to
this drive.
6.2. Repair of Seanet Pro
If the Seanet SCU (v5) is booting up normally and only the Seanet software is giving
a problem then, as a first level recovery, the Seanet Pro software can be re-installed
from the D:\ drive.
Before Re-Installing Seanet Pro, it is advisable to first remove the existing Seanet
Pro installation. This can be performed through
Control Panel
–
Programs