![Tritech Dual Frequency Echosounder Product Manual Download Page 39](http://html1.mh-extra.com/html/tritech/dual-frequency-echosounder/dual-frequency-echosounder_product-manual_1168957039.webp)
Configuration
Altimeter Product Manual
0286-SOM-00001, Issue: 09
39
© Tritech International Ltd.
SW1 Dip Switches
Input/Output
ID
1
2
3
4
5
6
String
Output
Format
Output
Behaviour
Output if
no echo
received
Interrogate
Character
4
0
0
1
0
0
0
000.000m
Interrogated
Zero
Z
5
1
0
1
0
0
0
000.000m
Free Running
Zero
n/a
6
0
1
1
0
0
0
000.000m
Interrogated
Maximum
Z
7
1
1
1
0
0
0
000.000m
Free Running
Maximum
n/a
8
0
0
0
1
0
0
00.000m
Interrogated
Zero
Z
9
1
0
0
1
0
0
00.000m
Free Running
Zero
n/a
10
0
1
0
1
0
0
00.000m
Interrogated
Maximum
Z
11
1
1
0
1
0
0
00.000m
Free Running
Maximum
n/a
12
0
0
1
1
0
0
000.00m
Interrogated
Zero
Z
13
1
0
1
1
0
0
000.00m
Free Running
Zero
n/a
14
0
1
1
1
0
0
000.00m
Interrogated
Maximum
Z
15
1
1
1
1
0
0
000.00m
Free Running
Maximum
n/a
16
0
0
0
0
1
0
Bathymetric
Interrogated
Zero
Z
17
1
0
0
0
1
0
NMEA
Free Running
Zero
n/a
18
0
1
0
0
1
0
NMEA
Free Running
Maximum
n/a
32
0
0
0
0
0
1
A000.000m
Interrogated
Zero
A
33
1
0
0
0
0
1
B000.000m
Interrogated
Zero
B
34
0
1
0
0
0
1
C000.000m
Interrogated
Zero
C
35
1
1
0
0
0
1
D000.000m
Interrogated
Zero
D
36
0
0
1
0
0
1
E000.000m
Interrogated
Zero
E
37
1
0
1
0
0
1
F000.000m
Interrogated
Zero
F
38
0
1
1
0
0
1
G000.000m
Interrogated
Zero
G
39
1
1
1
0
0
1
H000.000m
Interrogated
Zero
H
40
0
0
0
1
0
1
A000.000m
Interrogated
Maximum
A
41
1
0
0
1
0
1
B000.000m
Interrogated
Maximum
B
42
0
1
0
1
0
1
C000.000m
Interrogated
Maximum
C
43
1
1
0
1
0
1
D000.000m
Interrogated
Maximum
D
44
0
0
1
1
0
1
E000.000m
Interrogated
Maximum
E
45
1
0
1
1
0
1
F000.000m
Interrogated
Maximum
F
46
0
1
1
1
0
1
G000.000m
Interrogated
Maximum
G
47
1
1
1
1
0
1
H000.000m
Interrogated
Maximum
H
Note
On SW1 settings with ID0 to ID3 are for factory use only. ID19 to ID31
and greater than ID47 relate to application specific configurations. If the
altimeter has a switch setting that is not listed, please contact Tritech prior
to making any changes.