![Tritech Dual Frequency Echosounder Product Manual Download Page 20](http://html1.mh-extra.com/html/tritech/dual-frequency-echosounder/dual-frequency-echosounder_product-manual_1168957020.webp)
Installation
Altimeter Product Manual
0286-SOM-00001, Issue: 09
20
© Tritech International Ltd.
Analogue Only Configuration
1
4
6
2
3
5
Tritech Waterblock
Pin
Function
Wire colour
1
(not used)
Yellow
2
(not used)
Blue
3
+V DC
Red
4
0V, Analogue Ground
Black
5
Analogue Output
Green
6
Chassis Ground
cable screen
Dual Frequency Echosounder Configuration
1
4
6
2
3
5
Tritech Waterblock
Pin
Function
Wire colour
1
RS232 Tx/RS485A
Yellow
2
RS232 Rx/RS485B
Blue
3
+V DC
Red
4
0V, RS232 GND,
AHRS ground
Black
5
AHRS RS232 free
running output
Green
6
Chassis Ground
cable screen
Note
The Dual Frequency Echosounder does not have an analogue output. This
function is used for the AHRS output.
Note
The AHRS output on pin 5 is
RS232 ONLY