Tripp Lite Wireless Console Extender B014-000 Owner'S Manual Download Page 7

7

Getting Started

Wireless Connection

The B014-000 has a default IP address of 192.168.1.101 with a subnet mask of 255.255.255.0.
Be sure to configure your computer's wireless card for a corresponding IP address. The valid
address ranges are:

192.168.1.1 ~ 192.168.1.89; and 192.168.102 ~ 192.168.1.255

Note: Addresses 192.168.1.90 to 192.168.1.100 cannot be used as they are reserved for system

diagnostics.

Logging In

The operation of the B014-000 is browser based. To begin, open your browser and specify the
B014-000's IP address and web page name in the browser's URL location bar. For example:

192.168.1.101/test.htm

Note: You must include a forward slash and the B014-000's web page name (in the example 

above, the web page name is test.htm). If you don't know the page name, get it from the 
B014-000 administrator.

The B014-000 login page appears:

Provide a valid Username and Password, then Click 

Login

to continue.

When you have successfully logged in, the Main Screen appears:

200507185 93-2464 B014-000 OM.qxd  3/27/2006  10:23 AM  Page 7

Summary of Contents for Wireless Console Extender B014-000

Page 1: ...is one of continuous improvement Specifications are subject to change without notice Wireless Console Extender Model B014 000 Tripp Lite World Headquarters 1111 W 35th Street Chicago IL 60609 USA 773...

Page 2: ...og File 25 Appendix Specifications 26 Rack Mounting 26 Troubleshooting 27 General Operation 27 Sun Systems 27 The Windows Client 27 The Java Client 28 Administrator Login Failure 28 FCC Radio TV Inter...

Page 3: ...000 After a connection has been established and authorization granted the remote computer can exchange keyboard video and mouse signals with the attached server or KVM switch just as if they were phy...

Page 4: ...s running on the unit that is connected to the B014 000 whether it is a KVM OSD display a server s desk top or a running program The user can then control the system from his console just as if he wer...

Page 5: ...ready to operate WLAN This LED blinks ORANGE when a wireless station is connected to the B014 000 and is transmitting receiving data WLAN Reset Press and release this switch to perform a B014 000 rese...

Page 6: ...Plug the local administrator s keyboard mouse and monitor into the Console Ports 2 Use the cable provided with this package to connect the B014 000 s KVM Port to the Keyboard Video and Mouse ports of...

Page 7: ...ystem diagnostics Logging In The operation of the B014 000 is browser based To begin open your browser and specify the B014 000 s IP address and web page name in the browser s URL location bar For exa...

Page 8: ...bility to make configuration changes depends on the permissions associated with your login informa tion see User Manager p 13 Note Be sure to click the Logout icon when you end your session The functi...

Page 9: ...led and cannot be changed 2 All screen displays in this chapter are for example purposes The actual screens that are displayed may vary slightly in appearance and wording General The General panel dis...

Page 10: ...what these numbers are set to since they have no effect An explanation of the fields is given in the table below Program This is the port number that must be specified when connecting from the Admini...

Page 11: ...access the system with B014 000 Client software The Web Page name lets the Administrator specify the web page that the user connects to when accessing the B014 000 with a browser The user must include...

Page 12: ...tinuous range of addresses key in the end number of the range Click OK when done To delete a filter select it and Click Remove To modify a filter select it and Click Edit The Edit dialog box is simila...

Page 13: ...table below Username A minimum of 6 and a maximum of 15 characters are allowed Password A minimum of 8 and a maximum of 15 characters are allowed Confirm You are asked to enter the password twice to e...

Page 14: ...rom a remote computer Login failure timeout sets the amount of time a remote computer must wait before attempting to login again after it has exceeded the number of allowed failures Working Mode If St...

Page 15: ...mply run a previously downloaded version of the program Each time you want to access the B014 000 you must log in to the web page with a valid username and password to download a fresh copy of the pro...

Page 16: ...ed on your screen To access the areas that are off screen move the mouse to the corner of the screen that is closest to the area you want to view and the screen will scroll 4 Click Switch to take over...

Page 17: ...r example the F12 key could substitute for the Alt key in which case F12 Tab substi tutes for Alt Tab and Ctrl F12 Del substitutes for Ctrl Alt Del See Configuring the Hotkeys on p 20 for details on s...

Page 18: ...tion set the mouse acceleration to None Control Panel Mouse Mouse Properties Motion WindowsXP Server2003 Set the mouse speed to the middle position disable Enhance Pointer Precision Control Panel Prin...

Page 19: ...ters local and remote Display to be confusing or annoying you can use this function to shrink the non functioning pointer down to a barely noticeable tiny circle which can be ignored Since this functi...

Page 20: ...quence Click Stop 4 Click Set 5 Repeat for any other actions you wish to set up Note You can use the same function keys for more than one action as long as the first key is not the same For example yo...

Page 21: ...he results use the Screen Position arrows to position the remote display manually RGB Drag the slider bars to adjust the RGB Red Green Blue values When an RGB value is increased the RGB component of t...

Page 22: ...7 Click the Java Client icon 2 In the dialog box select Open Note If the browser won t open the Java Client program save the program to disk and with your browser still open Launch it after the save...

Page 23: ...e images such as motion images may display poorly because of net lag or insufficient computing power on the local machine 4 If the local and remote mouse pointers get out of sync use the Mouse Synchro...

Page 24: ...s 1 Click the Mouse Synchronization button The remote mouse pointer moves to the upper left area of the screen 2 Move your local mouse pointer directly over the remote mouse pointer and Click Lock LED...

Page 25: ...to a log file This is stored as a searchable database To view the contents of the log file click the Log icon at the left of the web page A screen similar to the one below appears To clear the log fil...

Page 26: ...er Consumption 1800 mA Protocols IEEE 802 11b Environment Operating Temperature 0 40 C Storage Temperature 0 60 C Humidity 0 80 RH Housing Metal Weight 0 51kg Dimensions L x W x H 17 x 10 x 1 7 in Rac...

Page 27: ...vers 1 Go to OK mode and issue the following commands setenv output device screen r1024x768x60 reset all Under XWindow 1 Open a console and issue the following command ffbconfig res 1024x768x60 2 Log...

Page 28: ...performance deteriorates Administrator Login Failure If you are unable to perform an Administrator login because the Username and Password information has become corrupted or you have forgotten it you...

Page 29: ...TRIPP LITE service center Products must be returned to TRIPP LITE or an authorized TRIPP LITE service center with transportation charges prepaid and must be accompa nied by a brief description of the...

Page 30: ...n 28 J Java Client 22 Keypad 24 Operation 22 Toolbar 23 Troubleshooting 28 L Log File 25 Main Screen 25 Log Server 4 Login Failure 14 Invalid login 28 Login Page 7 M MAC Address 9 Main Screen 8 Mouse...

Page 31: ...31 The policy of TRIPP LITE is one of continuous improvement Specifications are subject to change without notice This product designed and engineered in the USA...

Page 32: ...Tripp Lite World Headquarters 1111 W 35th Street Chicago IL 60609 USA 773 869 1234 www tripplite com 200507185 93 2464...

Reviews: