Introduction

The Administrator and Client utilities make the unit installation, maintenance and operation
easy. System administrators can handle a multitude of tasks with ease - from installing and run-
ning GUI applications, to BIOS level troubleshooting, routine monitoring, concurrent mainte-
nance, system administration, rebooting and even pre-booting functions.

The Administrator Utility is used to configure the system, limit access from remote computers,
manage users and maintain the system with firmware and software module updates.

The Log Server records all the events that take place on the B014-000 for the administrator to
analyze.

Both a Windows GUI Client and a Java Client are provided for IP connection and login to the
unit from anywhere on the net. The client software allows the user to view and control the
servers connected to the B014-000. The Java-based client ensures that the B014-000 is plat-
form independent and is able to work with all operating systems.

Once successfully connected and logged in, the user's screen displays whatever is running on
the unit that is connected to the B014-000 (whether it is a KVM OSD display, a server's desk-
top or a running program).  The user can then control the system from his console just as if he
were there.

Note: If you use more than one B014-000, the units must be at least 1000 ft. apart.

Features

• Wireless remote access of KVM switches or servers (IEEE 802.11b WLAN)

• Advanced security features: password protection; advanced encryption technologies

• High video resolution: up to 1600 x 1200 DDC2B

• Windows GUI and Java based Client software; Java client works with all operating systems.

• Firmware upgradeable via WLAN Ethernet connection.

• Multiple user accounts

System Requirements

• It is recommended that the computers used to access the B014-000 have at least a P III 

1 GHz processor and have the screen resolution set to 1024 x 768.

• For the Windows Client, you require DirectX 7.0 or higher installed.

• For the Java Client, you require Sun's Java 2 JRE 1.4 or higher.

• Only 

non-interlaced

video signals at the following resolutions and refresh rates are supported:

Resolution Refresh 

Rates

640 x 480 

60, 70, 75, 85, 90, 100, 120

720 x 400 

70, 75

800 x 600 

56, 60, 70, 75, 85, 90, 100, 120

1024 x 768 

60, 70, 75, 85, 90, 100

1152 x 864 

60, 70, 75, 85

1280 x 1024 

60, 70, 75

1600 x 1200 

60

200507185 93-2464 B014-000 OM.qxd  3/27/2006  10:23 AM  Page 4

Summary of Contents for Wireless Console Extender B014-000

Page 1: ...is one of continuous improvement Specifications are subject to change without notice Wireless Console Extender Model B014 000 Tripp Lite World Headquarters 1111 W 35th Street Chicago IL 60609 USA 773...

Page 2: ...og File 25 Appendix Specifications 26 Rack Mounting 26 Troubleshooting 27 General Operation 27 Sun Systems 27 The Windows Client 27 The Java Client 28 Administrator Login Failure 28 FCC Radio TV Inter...

Page 3: ...000 After a connection has been established and authorization granted the remote computer can exchange keyboard video and mouse signals with the attached server or KVM switch just as if they were phy...

Page 4: ...s running on the unit that is connected to the B014 000 whether it is a KVM OSD display a server s desk top or a running program The user can then control the system from his console just as if he wer...

Page 5: ...ready to operate WLAN This LED blinks ORANGE when a wireless station is connected to the B014 000 and is transmitting receiving data WLAN Reset Press and release this switch to perform a B014 000 rese...

Page 6: ...Plug the local administrator s keyboard mouse and monitor into the Console Ports 2 Use the cable provided with this package to connect the B014 000 s KVM Port to the Keyboard Video and Mouse ports of...

Page 7: ...ystem diagnostics Logging In The operation of the B014 000 is browser based To begin open your browser and specify the B014 000 s IP address and web page name in the browser s URL location bar For exa...

Page 8: ...bility to make configuration changes depends on the permissions associated with your login informa tion see User Manager p 13 Note Be sure to click the Logout icon when you end your session The functi...

Page 9: ...led and cannot be changed 2 All screen displays in this chapter are for example purposes The actual screens that are displayed may vary slightly in appearance and wording General The General panel dis...

Page 10: ...what these numbers are set to since they have no effect An explanation of the fields is given in the table below Program This is the port number that must be specified when connecting from the Admini...

Page 11: ...access the system with B014 000 Client software The Web Page name lets the Administrator specify the web page that the user connects to when accessing the B014 000 with a browser The user must include...

Page 12: ...tinuous range of addresses key in the end number of the range Click OK when done To delete a filter select it and Click Remove To modify a filter select it and Click Edit The Edit dialog box is simila...

Page 13: ...table below Username A minimum of 6 and a maximum of 15 characters are allowed Password A minimum of 8 and a maximum of 15 characters are allowed Confirm You are asked to enter the password twice to e...

Page 14: ...rom a remote computer Login failure timeout sets the amount of time a remote computer must wait before attempting to login again after it has exceeded the number of allowed failures Working Mode If St...

Page 15: ...mply run a previously downloaded version of the program Each time you want to access the B014 000 you must log in to the web page with a valid username and password to download a fresh copy of the pro...

Page 16: ...ed on your screen To access the areas that are off screen move the mouse to the corner of the screen that is closest to the area you want to view and the screen will scroll 4 Click Switch to take over...

Page 17: ...r example the F12 key could substitute for the Alt key in which case F12 Tab substi tutes for Alt Tab and Ctrl F12 Del substitutes for Ctrl Alt Del See Configuring the Hotkeys on p 20 for details on s...

Page 18: ...tion set the mouse acceleration to None Control Panel Mouse Mouse Properties Motion WindowsXP Server2003 Set the mouse speed to the middle position disable Enhance Pointer Precision Control Panel Prin...

Page 19: ...ters local and remote Display to be confusing or annoying you can use this function to shrink the non functioning pointer down to a barely noticeable tiny circle which can be ignored Since this functi...

Page 20: ...quence Click Stop 4 Click Set 5 Repeat for any other actions you wish to set up Note You can use the same function keys for more than one action as long as the first key is not the same For example yo...

Page 21: ...he results use the Screen Position arrows to position the remote display manually RGB Drag the slider bars to adjust the RGB Red Green Blue values When an RGB value is increased the RGB component of t...

Page 22: ...7 Click the Java Client icon 2 In the dialog box select Open Note If the browser won t open the Java Client program save the program to disk and with your browser still open Launch it after the save...

Page 23: ...e images such as motion images may display poorly because of net lag or insufficient computing power on the local machine 4 If the local and remote mouse pointers get out of sync use the Mouse Synchro...

Page 24: ...s 1 Click the Mouse Synchronization button The remote mouse pointer moves to the upper left area of the screen 2 Move your local mouse pointer directly over the remote mouse pointer and Click Lock LED...

Page 25: ...to a log file This is stored as a searchable database To view the contents of the log file click the Log icon at the left of the web page A screen similar to the one below appears To clear the log fil...

Page 26: ...er Consumption 1800 mA Protocols IEEE 802 11b Environment Operating Temperature 0 40 C Storage Temperature 0 60 C Humidity 0 80 RH Housing Metal Weight 0 51kg Dimensions L x W x H 17 x 10 x 1 7 in Rac...

Page 27: ...vers 1 Go to OK mode and issue the following commands setenv output device screen r1024x768x60 reset all Under XWindow 1 Open a console and issue the following command ffbconfig res 1024x768x60 2 Log...

Page 28: ...performance deteriorates Administrator Login Failure If you are unable to perform an Administrator login because the Username and Password information has become corrupted or you have forgotten it you...

Page 29: ...TRIPP LITE service center Products must be returned to TRIPP LITE or an authorized TRIPP LITE service center with transportation charges prepaid and must be accompa nied by a brief description of the...

Page 30: ...n 28 J Java Client 22 Keypad 24 Operation 22 Toolbar 23 Troubleshooting 28 L Log File 25 Main Screen 25 Log Server 4 Login Failure 14 Invalid login 28 Login Page 7 M MAC Address 9 Main Screen 8 Mouse...

Page 31: ...31 The policy of TRIPP LITE is one of continuous improvement Specifications are subject to change without notice This product designed and engineered in the USA...

Page 32: ...Tripp Lite World Headquarters 1111 W 35th Street Chicago IL 60609 USA 773 869 1234 www tripplite com 200507185 93 2464...

Reviews: