background image

Nominal input
voltage description

120V factory default

UPS input
connection type

5-15P

Input circuit
breaker

15A

UPS Input cord
length (ft.)

10

UPS Input cord
length (m)

3

Recommended
Electrical Service

15A 120V

BATTERY

Full load runtime
(minutes)

4.5 min. (1350w)

Half load runtime
(minutes)

14 min. (675w)

Expandable
battery runtime

Extended runtime supported via optional external battery packs

External battery
pack compatibility

BP48V24-2U

 (limit 1); 

BP48V60RT-3U

 (multi-pack compatible)

Expandable
runtime
description

External battery configurations require the use of Tripp Lite's External Battery Configuration Software, see manual for
details

DC system voltage
(VDC)

48

Battery recharge
rate (included
batteries)

Less than 3 hours from 10% to 90%

Replacement
battery cartridge
(internal UPS
battery
replacement)

RBC48-SUTWR

Battery Access

Battery access door

Battery
replacement
description

Hot-swappable, user replaceable batteries

VOLTAGE REGULATION

Voltage regulation
description

Online, double-conversion power conditioning

Overvoltage
correction

2% output voltage regulation during overvoltages to 150

Undervoltage
correction

2% output voltage regulation during undervoltages to 55V (33% load), 70V (70% load), 100V (100% load)

LEDS ALARMS & SWITCHES

Front panel LCD
display

Front panel LCD information and configuration screen offers detailed UPS and site power status and operating data,
plus configuration of voltage, frequency, operating mode, alarm function and a variety of additional options

Alarms

Audible alarm indicates UPS startup, power-failure, low-battery, overload, UPS fault and remote shutdown conditions

Summary of Contents for SmartOnline SU1500XLCD

Page 1: ...meters and line power status Included PowerAlert power management software supports an unlimited number of network UPS systems The SU1500XLCD also accepts an optional SNMPWEBCARD accessory that enables the UPS to operate as a managed device on the network It comes backed by a 2 year warranty and 250 000 of Ultimate Lifetime Insurance Package Includes SU1500XLCD SmartOnline Tower UPS System PowerAl...

Page 2: ... provides surge protection for a standard phone or network connection cable not included EMI RFI Line Noise Filtering Various electrical and radio sources can cause disruptive interference on the AC line This line noise is a common cause of incremental hardware damage data corruption and audio video performance problems The SU1500XLCD incorporates technology that filters out disruptive line noise ...

Page 3: ...ut frequency on startup Output matches input frequency when 5Hz of nominal Output is regulated to 0 05Hz when input frequency exceeds 5Hz of nominal UPS switches to battery mode when input frequency is below 40Hz or above 70Hz FREQUENCY REGULATION CONVERSION MODE Output is regulated to 0 05Hz of selected output frequency when input is 40 to 70Hz UPS switches to battery mode when input frequency is...

Page 4: ...teries Less than 3 hours from 10 to 90 Replacement battery cartridge internal UPS battery replacement RBC48 SUTWR Battery Access Battery access door Battery replacement description Hot swappable user replaceable batteries VOLTAGE REGULATION Voltage regulation description Online double conversion power conditioning Overvoltage correction 2 output voltage regulation during overvoltages to 150 Underv...

Page 5: ...ise suppression Yes PHYSICAL Installation form factors supported with included accessories Tower Primary form factor Tower UPS Power Module dimensions in primary form factor height x width x depth inches 10 2 x 9 x 19 5 UPS Power Module dimensions in primary form factor height x width x depth cm 25 9 x 22 9 x 49 5 UPS Power Module weight lbs 52 3 UPS Power Module weight kg 23 7 UPS Shipping dimens...

Page 6: ...ommunications cable USB and DB9 cabling included WatchDog compatibility Supports Watchdog application OS and hard reboot restart options for remote applications LINE BATTERY TRANSFER Transfer time Zero transfer time 0 ms in online double conversion and frequency regulation conversion modes Low voltage transfer to battery power setpoint 55V 33 load 70V 70 load 100V 100 load High voltage transfer to...

Page 7: ...uires ENVIROSENSE 1 PDUB15 Single Phase Hot Swap PDU 15A 120V 2U Horizontal Rackmount 8 NEMA 5 15R outlets set of 2 NEMA 5 15P input plugs 1 PDUMH15AT Single Phase Auto Transfer Switch Metered PDU 15A 120V 1U Horizontal Rackmount 8 NEMA 5 15R outlets 2 NEMA 5 15P inputs 1 PDUMNV15 Single Phase Monitored PDU 15A 120V 0U Vertical Rackmount 16 NEMA 5 15R outlets NEMA 5 15P input plug 1 PDUMV15NET Sin...

Reviews: