background image

REPLACING THE BATTERY

 

 

USER’S MANUAL 

GR600/ GR800/ GR1200/ GR1800/ GR2000

 

 

This manual contains important safety instructions. Please follow all instructions during installation. Read this manual thoroughly before unpacking, 
installing or operating. 

 
Caution: Risk of Electric Shock 

 

The UPS contains batteries.    The output outlets may be electrically live even when the UPS is disconnected from the AC mains. 

 

The UPS contains potentially hazardous voltages.    Do not open the units as there are no user serviceable parts.    All maintenance and servicing 
should be performed by qualified service personnel.   

 

Risk of electric shock, Battery Circuit is not isolated from AC input, hazardous voltage may exist between battery terminals and ground. Test 
before servicing and use insulated tools. 
 

NOTE: 

The UPS is designed to be for use with computer loads only. 

Caution

Do not connect a laser printer to the UPS.     

A laser printer draws significantly more power than other types of equipment and may overload the UPS.

 

SETUP 

Inspection 

 

Inspect the UPS upon receipt. 
Notify the carrier and dealer if there 
is damage. The package is 
recyclable; save it for reuse or 
dispose of it properly. 
 

Inspect accessories: 

 

Power cable 1PCS 

USER MANUAL 1PCS

 

Choose an installation location 
 

-  Avoid locations that are excessively humid, near water, 

near heat sources or in direct sunlight 

-  Allow 1inch (2.5cm) clearance on each side of the UPS.

 

 

 

Connecting Equipment and Power to the UPS 

 
 
 
 
 
 
 
 
 
 

Connect Modem/ Phone / Network for Surge Protection (Optional) 

 
 
 
 

ConnectInterface Device 
 

 

Turn ON/OFF the UPS 
 

Turn on the UPS: Press the UPS 
On/OFF Switch for approx. 3 
seconds, then the Buzzer sounds 
twice, the UPS will start-up.   
Turn off the UPS: Press the UPS 
On/OFF Switch for approx. 3 
seconds, then the Buzzer sounds 
twice, the UPS will shutdown. 

Cold Start Function 

When the UPS is OFF and no utility input 
power is present, use the “Cold Start” 
feature to apply power to the loads from 
UPS‘s battery. Press the “ON/OFF” switch 
untilthe UPS beeps. 

Software Download and Installation 

Please follow steps below to download and install monitoring software: 
1. Go to the website http://www.ablerex.com.sg/downloads.html 
2. Depending on the computer OS, select Emily software (for Win 7&8 OS, select Emily2) and click download. 
3. Follow the on-screen instructions to install the software. 
4. When the computer restarts, the monitoring software automatically search and connects to the UPS.

 

FRONT PANEL EXPLANATIONS

 

GR600/GR800

–LED FRONT   

PANEL (STANDARD)

 

Symbol

 

LED 
Color

 

Description/function 

GR600/GR800/R1200/GR1800/GR2000 

 

– LCD FRONT PANEL (OPTION) 

 

 

 

N/A

 

Turn-on/Turn-off Switch

 

 

 

Green

 

Lit: Line mode 
Dim: Abnormal input 
voltage and frequency   

1.Line mode

 

4. Battery capacity

 

7.Fault

 

 

Yellow

 

Lit: Battery mode 
Flashing: Battery Low

 

2.Battery mode

 

5. Load level

 

8.Tack switch for 
Turn-on/Turn-off

 

3.AVR mode

 

6.Measurement   
Target & Value

 

 

 

Red

 

Lit: System malfunction   
or abnormal

 

GR1200/GR1800/GR2000 

– LED     

FRONT PANEL(STANDARD) 

Symbol

 

LED 

Color

 

Description/function

 

REAR PANEL EXPLANATIONS

 

 

 

N/A

 

Turn-on/Turn-off Switch

 

 

GR600/GR800 REAR PANEL 

1.  AC Input Outlet 
2.  Fuse 
3.  Output Connector: 

4x Thailand Outlets 

4.  USB (Standard)   

 

 

GR1200/GR1800/GR2000 REAR PANEL 

1.  AC Input Outlet 
2.  Fuse 
3.  Output Connector: 
        6x Thailand Outlets 
4.  USB (Standard)   
5.  Fan 

 

 

Green

 

Lit: Line mode 
Flashing: Battery mode

 

 

Red

 

Lit: System malfunction or 
abnormal

 

 

 

N/A

 

Load

 

 

N/A

 

Battery

 

 

Green

 

Load Percentage/   
Battery Capacity

 

Step1: Connect the UPS to the 
AC mains. 
Step2: Connect the equipment 
to the UPS output outlets. 
Step3: Switch on the AC Mains, 
follow by the UPS then the 
equipment last. 
*Plug the UPS into the AC Mains 
to charge for 8 hours before 
using the UPS. 

-  For modem/phone line protection, 

connect equipment to the RJ11 
port using RJ11 cable. 

-  For surge protection, connect 

equipment to the RJ45 port using 
Ethernet/RJ45 cable. 

 

The UPS is equipped with 
two interface ports: a USB 
port (Standard) and a 9-pin 
RS232 port (Optional) 
allowing advanced 
communication network 
between the UPS and a 
computer (network).

 



192321982006000

 

Reviews: