2
Important Safety Instructions
SAVE THESE INSTRUCTIONS
This manual contains instructions and warnings that should be followed during the installation,
operation and storage of this product. Failure to heed these warnings will void your warranty.
UPS Location Warnings
• Install the UPS indoors, away from excess moisture, temperature extremes, conductive contaminants,
dust and direct sunlight.
• For best performance, keep the indoor temperature between 32º F and 104º F (0º C and 40º C).
• Leave adequate space around all sides of the UPS for proper ventilation.
•
Do not mount the unit with its front or rear panel facing down (at any angle). Mounting in this
manner will seriously inhibit the unit’s internal cooling, eventually causing product damage
not covered under warranty.
UPS Connection Warnings
• Connect the UPS to a properly grounded AC power outlet. Do not plug the UPS into itself; this will
damage the UPS.
• Do not modify the UPS input connector, and do not use an adapter that would eliminate the ground
connection of the UPS.
• Do not use extension cords to connect the UPS to an AC outlet.
• If the UPS receives power from a motor-powered AC generator, the generator must provide clean,
filtered, computer-grade output.
Equipment Connection Warnings
• Use of this equipment in life support applications where failure of this equipment can reasonably
be expected to cause the failure of the life support equipment or to significantly affect its safety
or effectiveness is not recommended. Do not use this equipment in the presence of a flammable
anesthetic mixture with air, oxygen or nitrous oxide.
• Do not connect surge suppressors to the output of the UPS. This might damage the UPS and will
void the surge suppressor and UPS warranties.
Battery Warnings
• The UPS does not require routine maintenance. There are no user-serviceable parts inside. Do not
open the UPS for any reason.
• Batteries can present a risk of electrical shock and burn from high short-circuit current. Observe
proper precautions. Do not dispose of the batteries in a fire. Do not open the UPS or batteries. Do not
short or bridge the battery terminals with any object. Unplug and turn off the UPS before performing
battery replacement. Use tools with insulated handles. There are no user-serviceable parts inside the
UPS. Battery replacement should be performed only by authorized service personnel using the same
number and type of batteries (Sealed Lead-Acid). The batteries are recyclable. Refer to your local
codes for disposal requirements or in the USA only call 1-800-SAV-LEAD or 1-800-8-BATTERY (1-
800-822-8837) or visit www.rbrc.com for recycling information. Tripp Lite offers a complete line of
UPS System Replacement Battery Cartridges (R.B.C.).Visit Tripp Lite on the Web at www.tripplite.
com/support/battery/index.cfm to locate the specific replacement battery for your UPS.
• Do not operate the UPS without batteries. Do not attempt to add external batteries to the UPS.