Operation

Power Module General Status

Description

Address

Value

Unit

Power Module ID / General Status

0x048C

Lo: ID (1-4), Hi: Status

Power Module ID / General Status

0x048D

Power Module ID / General Status

0x048E

Power Module ID / General Status

0x048F

Reserved

0x0490

Reserved

0x0491

Power Module General Status:
B0: The power module exists or the power module is powered
B1:
B2:
B3:
B4:
B5:

B6:
B7: Fault shutdown

Power Module PFC Status

Description

Address

Value

Unit

Power Module ID

0x0492

1-4

PFC Status 0,1

0x0493

Lo: Status 0, Hi: Status 1

Power Module ID

0x0494

PFC Status 0,1

0x0495

Power Module ID

0x0496

PFC Status 0,1

0x0497

Power Module ID

0x0498

PFC Status 0,1

0x0499

Reserved

0x049A

Reserved

0x049B

Reserved

0x049C

Reserved

0x049D

PFC Status:
B0: PFC fuse open shutdown
B1: PFC over temperature warning
B2: PFC over temperature shutdown
B3: DC bus over voltage warning
B4: DC bus over voltage shutdown
B5: DC bus under voltage warning
B6: DC bus under voltage shutdown
B7: PFC circuit general fault
B8: Fan failure
B9: TBD
B10: TBD
B11: TBD
B12: Inner communication failure
B13: TBD
B14: TBD
B15: Not calibrated (used to indicate whether the power module has been calibrated)

Summary of Contents for MODBUSCARD

Page 1: ...ght 2018 Tripp Lite All rights reserved PROTECT YOUR INVESTMENT Register your product for quicker service and ultimate peace of mind You could also win an ISOBAR6ULTRA surge protector a 100 value www...

Page 2: ...Single Registers Provides communication through RS 232 RS 485 or RS 422 interfaces Simultaneous communication through RS 232 and RS 485 or RS 232 and RS 422 connection interfaces A MODBUS Device ID C...

Page 3: ...Note The communication methods chosen must have its configuration dip switches set prior to installing the MODBUSCARD into the UPS systems accessory slot Device ID Configuration Every MODBUS device n...

Page 4: ...GND Function Switch Value ON OFF SW 1 SW 2 OFF OFF MODBUS OFF ON ON MODBUS ON Baud Rate SW2 1 SW2 2 OFF OFF 2400 Default ON OFF 4800 OFF ON 9600 ON ON 19200 Parity Check SW2 3 OFF Disable Parity Check...

Page 5: ...efault ON OFF 4800 OFF ON 9600 ON ON 19200 Parity Check SW3 3 OFF Disable Parity Check Default ON Enable Parity Check SW3 4 OFF Even Parity Default ON Odd Parity Protocol SW3 5 SW3 6 OFF OFF MODBUS Pr...

Page 6: ...PC request Discrete Inputs Range 0x0100 0x012F Read Function 0x02 The Read Discrete Inputs function code is used to read 1 2000 contiguous status of Discrete Inputs in a remote device The starting add...

Page 7: ...s STS Over Alarm Bypass STS Fault 0x012C OK Bypass STS Fault Reserved 0x012D Reserved 0x012E Reserved 0x012F Note Your UPS may not support all fields Coils Range 0x0200 0x020F Read Function 0x01 Write...

Page 8: ...nsfer Voltage 0x0304 0 999 Voltage High Transfer Voltage 0x0305 0 999 Voltage Voltage Sensitivity 0x0306 0 Normal 1 Reduced 2 Low Last Battery Replace Date Year 0x0307 0 9999 Last Battery Replace Date...

Page 9: ...tage High Tx Voltage Point 0x0409 0 999 Voltage Low Tx Voltage Upper Bound 0x040A 0 999 Voltage Low Tx Voltage Lower Bound 0x040B 0 999 Voltage High Tx Voltage Upper Bound 0x040C 0 999 Voltage High Tx...

Page 10: ...ve Battery Temp 0x042B 0 999 Degrees Celsius Negative Battery Level 0x042C 0 999 Reserved 0x042D Reserved 0x042E Reserved 0x042F Input Status Description Address Value Unit Input Number Lines 0x0430 0...

Page 11: ...x0450 0 999 Output Voltage 12 0x0451 0 9999 0 1 Voltage Output Voltage 23 0x0452 0 9999 0 1 Voltage Output Voltage 31 0x0453 0 9999 0 1 Voltage Reserved 0x0454 Reserved 0x0455 Bypass Status Descriptio...

Page 12: ...Temperature 0x0469 0 999 Degrees Celsius Humidity 0x046A 0 999 Relay 1 0x046B 0 Off 1 On Relay 2 0x046C 0 Off 1 On Relay 3 0x046D 0 Off 1 On Relay 4 0x046E 0 Off 1 On Reserved 0x046F Reserved 0x0470 S...

Page 13: ...emp Byte 5 Lo T Phase Inverter Temperature Temp Byte 6 Hi B0 Temperature Warning 75C B1 High Temperature Shutdown 85C B2 Inverter Voltage Too Low B3 Inverter Voltage Too High B4 Overload Warning B5 Ov...

Page 14: ...Temp Byte 19 Reserved Temp Byte 20 Hi B5 Ambiance Over Temperature B7 Auxiliary Power Fail Note Currently TempStatus is not supported by UPS Operation Parallel Master ID Description Address Value Uni...

Page 15: ...1 4 PFC Status 0 1 0x0493 Lo Status 0 Hi Status 1 Power Module ID 0x0494 PFC Status 0 1 0x0495 Power Module ID 0x0496 PFC Status 0 1 0x0497 Power Module ID 0x0498 PFC Status 0 1 0x0499 Reserved 0x049...

Page 16: ...erter Voltage Abnormal B8 Inverter Circuit General Fault B9 DC Bus Over Voltage Shutdown B10 Inverter Overload B11 B12 Inner Communication Loss includes the communication to system or other modules B1...

Page 17: ...0x04BD 0 9999 0 1 Voltage Power Module ID 0x04BE 1 4 Temperature PFC 0x04BF 0 9999 0 1 Voltage Temperature TBD 0x04C0 0 9999 0 1 Voltage Temperature INV 0x04C1 0 9999 0 1 Voltage Temperature INV R 0x0...

Page 18: ...ule ID 0x04E2 1 4 Inverter Voltage R 0x04E3 0 9999 0 1 Voltage Inverter Voltage S 0x04E4 0 9999 0 1 Voltage Inverter Voltage T 0x04E5 0 9999 0 1 Voltage Power Module ID 0x04E6 1 4 Inverter Voltage R 0...

Page 19: ...Byte 7 Model Byte 8 9 0x0507 Lo Byte 8 Hi Byte 9 Model Byte 10 11 0x0508 Lo Byte 10 Hi Byte 11 Model Byte 12 13 0x0509 Lo Byte 12 Hi Byte 13 Model Byte 14 15 0x050A Lo Byte 14 Hi Byte 15 Reserved 0x05...

Page 20: ...ts and you may have other rights which vary from jurisdiction to jurisdiction WARNING The individual user should take care to determine prior to use whether this device is suitable adequate or safe fo...

Reviews: