background image

13

Logging In to the B051-000

The B051-000 IP remote access unit can be accessed in several ways: local console, 

web browser, non-browser Windows or Java client. This section describes the login 
procedures for each of these methods.

Local Console Login

When accessing the unit via local console, there is no login required except for what 
is required to access the connected computer or KVM switch. The local keyboard, 
monitor and mouse function the same as if they were connected directly to the 
computer or KVM.

Web Browser Login

To log into the IP remote access unit via web browser, follow the steps below. 

Note

: Windows Vista and later users who intend to use the unit’s Virtual Media feature must 

run Internet Explorer as an administrator. (See Virtual Media section in the Owner’s Manual for 

details.)

1. Open your browser and enter the IP address of the B051-000 as given to you by 

your system administrator. 

 

Note

: For security purposes, a login string may have been set by the administrator. If so, you 

must include a forward slash and the login string following the IP address. For example, to 
access a B051-000 with an IP address of 192.168.0.60 and a login string of B051000, you 

would enter the URL as 192.168.0.60/B051000.

2. When logging in for the first time, a security alert appears to inform you that the 

device’s certificate is not trusted, and asks if you want to proceed. The certificate 
can be trusted, but the alert is triggered because the certificate’s name is not 
found in the browser’s list of trusted certificates.

  You have two options:

•  

If working on a computer other than your own, choose to proceed with your 
session, even though the certificate is not trusted.

•  

If working on your own computer, install the certificate by following the steps 
below. 

 

Note

: You may need to run Internet Explorer as an administrator to install the certificate.

a. In the Security Alert dialog box, click 

View Certificate

. The certificate 

information dialog box appears.

b. Click 

Install Certificate

.

c. Follow the installation wizard to complete the certificate installation. The 

default options are recommend.

d. When a caution screen appears asking you to confirm installing the certificate, 

click 

Yes

.

e. Click 

Finish

 to complete the installation and click 

OK

 to close the dialog box. 

The certificate is now trusted.

 

17-11-282  93-373C.indd   13

12/5/2017   4:00:29 PM

Summary of Contents for IP Remote Access Unit

Page 1: ...ltimate peace of mind You could also win an ISOBAR6ULTRA surge protector a 100 value www tripplite com warranty 1111 W 35th Street Chicago IL 60609 USA www tripplite com support Copyright 2017 Tripp L...

Page 2: ...t results we recommend a network transfer speed of at least 512 kbps For the browser based Windows Client at least 60 MB of memory must be available after installation For the non browser Windows Clie...

Page 3: ...r 64 bit is not supported Front View 1 LAN Port The Cat5e 6 cable that connects the B051 000 to a network plugs in here 2 LUC Port This laptop USB console LUC port allows a laptop to be used as a cons...

Page 4: ...mes with a 0U rack mount kit so the unit can be conveniently mounted on a system rack To rack mount the unit 1 Remove the two original screws from the bottom of the unit near the rear of the unit 2 Us...

Page 5: ...on 2 Use the larger screws supplied with the rack mount kit to screw the DIN rail brackets to the mounting bracket as shown in the diagram 3 Hang the unit on the DIN rail Rack Mounting Screw the brack...

Page 6: ...the PS 2 ports on a computer or KVM switch Use the cable kit appropriate to your installation 4 Optional Connect a modem or other RS 232 serial device to the unit s RS 232 serial port 5 Using a stand...

Page 7: ...Determination Administrators logging in for the first time must access the B051 000 in order to provide an IP address so users can connect You can do this via Web Browser the IP Installer utility or t...

Page 8: ...ng on your network 6 The IP Address Subnet Mask and Default Gateway fields will be activated upon checking the Set IP address manually Fixed IP checkbox Fill in these fields with information appropria...

Page 9: ...its Admin Utility without using a web browser The applications function is the same However the Windows Client is designed for Windows computers whereas the Java client is designed for either Windows...

Page 10: ...the unit it will not be displayed in the list You must manually enter the IP address in the IP Address field then click the Connect button 3 When accessing either the Windows or the Java client for th...

Page 11: ...e tool bar at the top of the screen click the Open GUI icon to open the unit s administrative interface The non browser interface contains most of the features contained in the browser version but are...

Page 12: ...ter Double click on the file to open the IP Installer utility 2 Select the B051 000 from the Device List Note If the list is empty or your device doesn t appear click the Enumerate button to refresh t...

Page 13: ...ess For example to access a B051 000 with an IP address of 192 168 0 60 and a login string of B051000 you would enter the URL as 192 168 0 60 B051000 2 When logging in for the first time a security al...

Page 14: ...tely access the B051 000 and its Admin Utility without using a web browser The applications function is the same However the Windows Client is designed for Windows computers whereas the Java client is...

Page 15: ...the IP address as given to you by your system administrator in the IP Address field and then click the Connect button 5 Upon clicking the Connect button you will be prompted to enter a Username and P...

Page 16: ...FREE Tripp Lite product No purchase necessary Void where prohibited Some restrictions apply See website for details FCC Part 68 Notice United States Only If your Modem Fax Protection causes harm to t...

Reviews: