background image

Frequency Compatibility

50 / 60 Hz

Output Voltage Regulation (Line
Mode)

120V (±20%)

Output Voltage Regulation (Battery
Mode)

120V (±10%)

UPS Output Receptacles (Surge
Suppression Only)

6 UPS outlets, 6 surge-only outlets

Load Management Receptacles

The ECO Energy-Saving option will automatically POWER OFF four designated ECO outlets when the device
connected to the MASTER load-sensing outlet is turned off (after approximately 3 minutes); ECO outlets will
immediately POWER ON when the device connected to the MASTER load-sensing outlet begins consuming 21
watts or more (see manual)

Output AC Waveform (AC Mode)

Pure sine wave

Output AC Waveform (Battery
Mode)

PWM sine wave

Nominal Output Voltage(s)
Supported

110V; 115V; 120V

Output Receptacles

(12) 5-15R

Individually Controllable Load Banks

No

BATTERY

Battery Type

Valve Regulated Lead Acid (VRLA)

Full Load Runtime (min.)

2.3 min. (425w)

Half Load Runtime (min.)

9 min. (212.5w)

Expandable Runtime

No

DC System Voltage (VDC)

12

Battery Recharge Rate (Included
Batteries)

8 hours from 10% to 90%

Battery Access

Battery access door

Battery Replacement Description

Replaceable internal batteries (see manual)

USER INTERFACE, ALERTS & CONTROLS

Front Panel LCD Display

Touchscreen LCD reports operating mode, input/output voltage, input/output frequency and load capacity

Switches

Switch controls power off/on status and ECO mode off/on status

Audible Alarm

UPS remains silent in battery backup mode; Alarm sounds only to report low-battery, fault, overload and replace-
battery conditions

SURGE / NOISE SUPPRESSION

UPS AC Suppression Joule Rating

316

UPS AC Suppression Response
Time

Instantaneous

UPS Dataline Suppression

1 line TEL/DSL or Ethernet

EMI / RFI AC Noise Suppression

Yes

3 / 5

Reviews: