Installation
Protecting Edge-Of-Network Source and
Equipment
The previous installation only protects your edge equipment
from surge, lightning or ESD damage. To protect both the
source and edge equipment, install two B110-SP-CAT-OD2
units in your application. A B110-SP-POE can be installed
instead of a second B110-SP-CAT-OD2 to protect the source if
the second unit will be installed indoors.
Note:
Use standard size Cat5e, Cat6 or Cat6a cables that feature a
wire gauge of 23/24 AWG. Slim category cables are not supported.
Maximum cable distance between two B110-SP-CAT-OD2 units is
328 ft. (100 m).
1.
Install a second B110-SP-CAT-OD2 between the first
B110-SP-CAT-OD2 unit and your source following steps 1-3
in
Protecting Edge-Of-Network Equipment
section.
Wireless Access Point
B110-SP-CAT-OD2
B110-SP-CAT-OD2
PoE Switch
To LAN